...........................................................................................................................................................................................................................................................................................................................................................................................................<br />
1.3 Operative Range<br />
<strong>AViTEQ</strong> unbalance motors are designed and used as single or double drives for<br />
vibration (conveyor) devices for discharging, conveying, feeding, compacting, loosening,<br />
dosing, and/or screening of bulk materials. The unbalance motors are not<br />
intended for any other purposes.<br />
As a three-phase cage motor, the unbalance motor is suited for use with 50 Hz or 60<br />
Hz three-phase mains supplies. Some special unbalance motor types are design-ed<br />
and built for single-phase operation for use with 50 Hz or 60 Hz mains supplies.<br />
NOTE<br />
<strong>Operating</strong> the unbalance motor with a frequency converter at a three-phase mains<br />
supply is allowed. The allowed frequency range for the output frequency of the<br />
frequency converter is 20 up to 50 Hz with a 50 Hz-mains frequency and 20 up to<br />
60 Hz with a 60 Hz-mains frequency. In case of doubt, please contact us!<br />
Never use in the following cases:<br />
• Do not use with mains voltages and mains frequencies that, according to the<br />
information on the type label, are not adapted for the unbalance motor.<br />
• Do not use in environmental temperatures below -20°C and above +40°C or<br />
+55°C depending on the type, or in tropical climate! The unbalance motors are<br />
designed for operation in moderate climate environments. Special versions for<br />
non-moderate climate environments might be possible on request.<br />
• Do not use at elevations above 1,000 m above sea level without first consulting<br />
<strong>AViTEQ</strong> Vibrationstechnik GmbH.<br />
• Do not use if an explosive gas atmospheres like a gas-, a vapour-, a mist-airmixture<br />
is existing or for conveying explosives.<br />
1.4 Installation an <strong>Operating</strong> Personnel<br />
Prior to installation and/or commissioning,<br />
you must be familiar with all details<br />
and connexion configurations of the<br />
unbalance motor.<br />
Persons involved with installation, commissioning, assembly, disassembly, adjustment<br />
or maintenance must have read and understood this operating manual in its<br />
entirety; in particular the safety notes. If you have any questions, we would be glad<br />
to help you!<br />
NOTE<br />
Please observe the following remarks, if the unbalance motor is operated in areas<br />
with the presence of combustible dust:<br />
• The selection of the drives and the installation of the units must be carried out by<br />
accordingly trained and qualified personnel in compliance with EN 61241-14.<br />
• The inspection and maintenance of the drives must be carried out by accordingly<br />
trained and qualified personnel in compliance with EN 61241-17.<br />
• Repair and overhaul of the drives, as far as allowed, must be carried out by<br />
accordingly trained and qualified personnel in compliance with IEC 61241-19.<br />
The unbalance motors are only allowed to be repaired by <strong>AViTEQ</strong><br />
Vibrationstechnik GmbH or by special trained and authorised service personnel.<br />
<strong>AViTEQ</strong> Vibrationstechnik GmbH is not liable for damage to property and/or<br />
persons in the case of neglect!<br />
All work on the electrical installation must only be carried out by qualified personnel<br />
(electricians or persons trained in electrical engineering according to EN 60204-1).<br />
...........................................................................................................................................................................................................................................................................................................................................................................................<br />