...........................................................................................................................................................................................................................................................................................................................................................................................................<br />
DANGER!<br />
Before swapping phases, disconnect all power to the unbalance motor and secure it<br />
against unintentional reconnexion. Check that no voltages are present before you<br />
swap!<br />
ATTENTION!<br />
Always ensure that both unbalance motors rotate in the correct direction. Even brief<br />
operation with a wrong direction of rotation may lead to major damage on the<br />
vibration (conveyor) device.<br />
5.2.3 Final Check<br />
<br />
<br />
<br />
<br />
<br />
Finally please check that both protective hoods are properly installed,<br />
further that all of the fixing screws of the protective hoods are tightened<br />
and the terminal box is closed properly.<br />
Verify that the combination consisting of unbalance motor(s) and vibration<br />
(conveyor) device works as intended. If required, correct the adjustment of<br />
the centrifugal weights.<br />
In case of double drives, make sure that both unbalance motors work with<br />
the correct direction of rotation!<br />
Make certain that no loose parts are in contact with the unbalance motor<br />
or vibration (conveyor) device. Malfunctions, noise and/or damage may<br />
otherwise result.<br />
Check the current draw of all unbalance motors. If the value exceeds the<br />
value that is shown on the type label of the unbalance motor, reduce the<br />
centrifugal force for lowering the current draw and contact <strong>AViTEQ</strong>. After<br />
reducing the centrifugal force check once more, if the current draw is<br />
lower than the value shown on the type label.<br />
DANGER!<br />
Short circuit or danger of electrocution during the following measurements! Observe<br />
the safety regulations when measuring voltage-carrying components! Take<br />
appropriate measures to prevent contact with voltage-carrying components!<br />
ATTENTION!<br />
It is totally prohibited that the current consumption of the unbalance motor exceeds<br />
the value of the nominal current specified on the type label, because this may lead to<br />
inadmissible temperatures.<br />
...........................................................................................................................................................................................................................................................................................................................................................................................<br />