...........................................................................................................................................................................................................................................................................................................................................................................................................<br />

DANGER!<br />

If you operate the unbalance motor in an area with the presence of combustible dust,<br />

never open the cover of the terminal box, as long as voltage is present at the<br />

terminals inside of the terminal box, because this is an ignition source and as a result<br />

may lead to an ignition of a potentially explosive atmosphere consisting of a dust-airmixture!<br />

DANGER!<br />

Inadequate installation may cause the unbalance motor to fall down possibly causing<br />

injuries. Ensure that the unbalance motor is bolted on tight to the working unit and<br />

take appropriate steps to ensure that the unbalance motor cannot fall down!<br />

Remaining under the unbalance motor or the vibration (conveyor) device is not<br />

allowed!<br />

DANGER!<br />

Parts that collide with other parts can lead to ignition sources. Before first<br />

commissioning, make sure that the vibration (conveyor) device can oscillate without<br />

colliding with other parts and that all screws are tightened correctly!<br />

DANGER!<br />

After switching off, an unbraked unbalance motor may excite the natural frequency<br />

of its support before coming to a halt. Make sure that the vibration (conveyor) device<br />

cannot jump out of its support! Always use a braking unit for unbalance motors of<br />

sizes UVG… and larger.<br />

DANGER!<br />

Danger of injuries! During operation the motor housing heats up. Expect surface<br />

temperatures up to +135°C!<br />

ATTENTION!<br />

Every unbalance motor must be operated with a separate motor-protective<br />

circuit breaker! It is not allowed to add up the currents of several unbalance<br />

motors and then operate them with a common motor-protective circuit breaker! The<br />

motor-protective circuit breaker has to be set to the value of the rated current<br />

(nominal current) of the unbalance motor, as it is shown on the type label of the<br />

unbalance motor!<br />

<strong>Operating</strong> with two drives, both drives have to be connected in a way that if one<br />

drive is switched off the second drive has to be switched off too. A single drive<br />

operation is not allowed in the case of double drives and may lead to a destruction<br />

of the unbalance motors and/or the vibration (conveyor) device! Always observe this!<br />

...........................................................................................................................................................................................................................................................................................................................................................................................<br />