...........................................................................................................................................................................................................................................................................................................................................................................................................<br />
DANGER!<br />
If you operate the unbalance motor in an area with the presence of combustible dust,<br />
never open the cover of the terminal box, as long as voltage is present at the<br />
terminals inside of the terminal box, because this is an ignition source and as a result<br />
may lead to an ignition of a potentially explosive atmosphere consisting of a dust-airmixture!<br />
DANGER!<br />
Inadequate installation may cause the unbalance motor to fall down possibly causing<br />
injuries. Ensure that the unbalance motor is bolted on tight to the working unit and<br />
take appropriate steps to ensure that the unbalance motor cannot fall down!<br />
Remaining under the unbalance motor or the vibration (conveyor) device is not<br />
allowed!<br />
DANGER!<br />
Parts that collide with other parts can lead to ignition sources. Before first<br />
commissioning, make sure that the vibration (conveyor) device can oscillate without<br />
colliding with other parts and that all screws are tightened correctly!<br />
DANGER!<br />
After switching off, an unbraked unbalance motor may excite the natural frequency<br />
of its support before coming to a halt. Make sure that the vibration (conveyor) device<br />
cannot jump out of its support! Always use a braking unit for unbalance motors of<br />
sizes UVG… and larger.<br />
DANGER!<br />
Danger of injuries! During operation the motor housing heats up. Expect surface<br />
temperatures up to +135°C!<br />
ATTENTION!<br />
Every unbalance motor must be operated with a separate motor-protective<br />
circuit breaker! It is not allowed to add up the currents of several unbalance<br />
motors and then operate them with a common motor-protective circuit breaker! The<br />
motor-protective circuit breaker has to be set to the value of the rated current<br />
(nominal current) of the unbalance motor, as it is shown on the type label of the<br />
unbalance motor!<br />
<strong>Operating</strong> with two drives, both drives have to be connected in a way that if one<br />
drive is switched off the second drive has to be switched off too. A single drive<br />
operation is not allowed in the case of double drives and may lead to a destruction<br />
of the unbalance motors and/or the vibration (conveyor) device! Always observe this!<br />
...........................................................................................................................................................................................................................................................................................................................................................................................<br />