K.Energy insulated wall panel system - PGA Consultants
K.Energy insulated wall panel system - PGA Consultants
K.Energy insulated wall panel system - PGA Consultants
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
K.<strong>Energy</strong> <strong>insulated</strong> <strong>wall</strong> <strong>panel</strong> <strong>system</strong><br />
120A - Metal Cladding<br />
Primary cladding fasteners Self tapping and self drilling screws (galvanized carbon steel) .<br />
Number and location of<br />
fasteners<br />
Sealing Cladding<br />
550A Seals<br />
1 N° fastener at every support rail fixed through <strong>panel</strong> trough plus intermediate fasteners<br />
at 450mm centers or as required by project specific calculations.<br />
.<br />
Horizontal - Rolled steel full interlocking male/female edges giving weather tight overlap joint.<br />
Vertical - Extended top profile with foam core and bottom profile cut back to give a fully sealed<br />
overlap joint (200mm) complete with 3 continuous rows of 6mm x 5mm butyl rubber sealant.<br />
554A Vapour seals<br />
Sealant tape: 20mm x 5mm closed cell foam vapour strip positioned in straight unbroken lines at <strong>panel</strong><br />
supports, parallel to and slightly back from end of <strong>panel</strong>. Do not allow tape to be stretched into position.<br />
Ensure continuity and effectiveness of seal, especially at sheet corners. Ensure adequate over-compression<br />
to achieve required vapour seal.<br />
Sealing of outer cladding <strong>system</strong> to be in accordance with NBS applicable to <strong>system</strong> selected<br />
43<br />
77<br />
Panel thickness<br />
Promisol 1001T <strong>wall</strong> <strong>panel</strong><br />
Ondafix vertical support rail<br />
Horizontal steelwork sheeting rail<br />
Main <strong>panel</strong> fixing screw as per<br />
job specific calculations<br />
Monobond butyl<br />
3 Rows of 6x5mm butyl rubber<br />
sealant (site applied)<br />
Top sheet stitcher fixing<br />
at 450 centres<br />
Illustrative only - Frequence 5.180.43 B <strong>wall</strong> sheet<br />
May be replaced by any suitable external steel or<br />
aluminium profile, "hi-tec" <strong>panel</strong>ling, timber<br />
cladding or reconstituted stone<br />
Low profile colour coated fixing at 180 (or 360)<br />
centres to suit design applied loading<br />
N° K005/2 - Sealing Joints 2 (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)