27.12.2014 Views

K.Energy insulated wall panel system - PGA Consultants

K.Energy insulated wall panel system - PGA Consultants

K.Energy insulated wall panel system - PGA Consultants

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

K.<strong>Energy</strong> <strong>insulated</strong> <strong>wall</strong> <strong>panel</strong> <strong>system</strong><br />

120A - Metal Cladding<br />

Accessories<br />

R<br />

Matching flashings and support zeds. Ondafix rails (1.5mm)<br />

Fittings and accessories generally<br />

221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where not<br />

specified, are to be types as recommended by ArcelorMittal - Arval.<br />

223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports which<br />

would otherwise be in contact with cladding or accessories after fixing.<br />

310A Purpose made<br />

cold formed<br />

metal<br />

accessories<br />

Material:<br />

Thickness/gauge:<br />

Finish/colour:<br />

43<br />

Galvanized cold rolled steel sheet grade S320 GD.<br />

0.75mm minimum.<br />

External - Colorissime range.<br />

Internal - Interior 912<br />

Workmanship as NBS Standard Section Z22.<br />

R<br />

Fix to K.<strong>Energy</strong> and/or Structure with 4.8mm stitcher screws (or rivets) at 450mm<br />

nominal centers.<br />

77<br />

Panel thickness<br />

Ondafix vertical support rail<br />

Promisol 1001T <strong>wall</strong> <strong>panel</strong><br />

Illustrative only - Frequence 5.180.43 B <strong>wall</strong> sheet<br />

May be replaced by any suitable external steel or<br />

aluminium profile, "hi-tec" <strong>panel</strong>ling, timber<br />

cladding or reconstituted stone<br />

Low profile colour coated fixing at 180 (or 360)<br />

centres to suit design applied loading<br />

Main <strong>panel</strong> fixing screw as per<br />

job specific calculations<br />

Horizontal steelwork sheeting rail<br />

6mm diameter bead of gun grade sealant<br />

Gun grade silicone fillet<br />

Cill flashing by others<br />

Note: These details are for guidance only.<br />

The individual building designer must<br />

satisfy him/herself of any and all cold<br />

bridging issues and adjust the final<br />

design layout accordingly.<br />

Closure flashing by others<br />

Brickwork<br />

N° K006 - Base Drip (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)