K.<strong>Energy</strong> <strong>insulated</strong> <strong>wall</strong> <strong>panel</strong> <strong>system</strong><br />
120A - Metal Cladding<br />
Accessories<br />
R<br />
Matching flashings and support zeds. Ondafix rails (1.5mm)<br />
Fittings and accessories generally<br />
221 Accessories Cappings, closure pieces, flashings, trims cills, gutters, fillers, spacers, tapes, sealants, fixings etc, where not<br />
specified, are to be types as recommended by ArcelorMittal - Arval.<br />
223 Isolating Tape A type recommended for the purpose by ArcelorMittal - Arval. Apply to those surfaces of supports which<br />
would otherwise be in contact with cladding or accessories after fixing.<br />
310A Purpose made<br />
cold formed<br />
metal<br />
accessories<br />
Material:<br />
Thickness/gauge:<br />
Finish/colour:<br />
43<br />
Galvanized cold rolled steel sheet grade S320 GD.<br />
0.75mm minimum.<br />
External - Colorissime range.<br />
Internal - Interior 912<br />
Workmanship as NBS Standard Section Z22.<br />
R<br />
Fix to K.<strong>Energy</strong> and/or Structure with 4.8mm stitcher screws (or rivets) at 450mm<br />
nominal centers.<br />
77<br />
Panel thickness<br />
Ondafix vertical support rail<br />
Promisol 1001T <strong>wall</strong> <strong>panel</strong><br />
Illustrative only - Frequence 5.180.43 B <strong>wall</strong> sheet<br />
May be replaced by any suitable external steel or<br />
aluminium profile, "hi-tec" <strong>panel</strong>ling, timber<br />
cladding or reconstituted stone<br />
Low profile colour coated fixing at 180 (or 360)<br />
centres to suit design applied loading<br />
Main <strong>panel</strong> fixing screw as per<br />
job specific calculations<br />
Horizontal steelwork sheeting rail<br />
6mm diameter bead of gun grade sealant<br />
Gun grade silicone fillet<br />
Cill flashing by others<br />
Note: These details are for guidance only.<br />
The individual building designer must<br />
satisfy him/herself of any and all cold<br />
bridging issues and adjust the final<br />
design layout accordingly.<br />
Closure flashing by others<br />
Brickwork<br />
N° K006 - Base Drip (Note: All installations should comply with the recommendations contained in MCRMA Techinical Papers N° 12 & 14; BS3200 and other relevant national standards)