09.11.2012 Views

VALVES - Norgren Pneumatics. Motion Control Equipment, Fluid ...

VALVES - Norgren Pneumatics. Motion Control Equipment, Fluid ...

VALVES - Norgren Pneumatics. Motion Control Equipment, Fluid ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

14<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

<strong>Norgren</strong>.com/usa – 303.794.2611 – help@amer.norgren.com<br />

Valve Manifolds VS26 Series<br />

Plug-in Mini ISO Valves<br />

2x2/2, 2x3/2, 5/2 and 5/3 valves, ISO 15407-2,<br />

2x2/2 Double solenoid actuated Softseal valves flow = 1.17 Cv (1150 l/min)<br />

1) Pilot air supply through port 1<br />

2) Pilot air supply through port 12/14<br />

Valve functions designations:<br />

NO = Normally open<br />

NC = Normally closed<br />

Size 26 mm<br />

Model Function Actuation Pilot Pilot pressure Operating Manual Voltage<br />

2 x 2/2 supply psi pressure psi (bar) override<br />

VS26SE11DF313A NC Sol/Spring Internal 44 to 145 1<br />

26" Hg to 145 (-0.9 to 10) Push only 24V DC 1.2W<br />

VS26SE11DF318A NC Sol/Spring Internal 44 to 145 1<br />

26" Hg to 145 (-0.9 to 10) Push only 115V AC 1.5VA<br />

VS26SE11DF213A NC Sol/Spring Internal 44 to 145 1<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24V DC 1.2W<br />

VS26SE11DF218A NC Sol/Spring Internal 44 to 145 1<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115V AC 1.5VA<br />

VS26SE11DF513A NC Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Extended, push only 24V DC 1.2W<br />

VS26SE11DF518A NC Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Extended, push only 115V AC 1.5VA<br />

VS26SE22DF313A NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 24V DC 1.2W<br />

VS26SE22DF318A NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 115V AC 1.5VA<br />

VS26SE22DF213A NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24V DC 1.2W<br />

VS26SE22DF218A NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115V AC 1.5VA<br />

VS26SE22DF513A NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24V DC 1.2W<br />

VS26SE22DF518A NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115V AC 1.5VA<br />

VS26SF11DF313A NO Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Push only 24V DC 1.2W<br />

VS26SF11DF318A NO Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Push only 115V AC 1.5VA<br />

VS26SF11DF213A NO Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Push & turn 24V DC 1.2W<br />

VS26SF11DF218A NO Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Push & turn 115V AC 1.5VA<br />

VS26SF11DF513A NO Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Extended, push only 24V DC 1.2W<br />

VS26SF11DF518A NO Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Extended, push only 115V AC 1.5VA<br />

VS26SF22DF313A NO Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 24V DC 1.2W<br />

VS26SF22DF318A NO Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 115V AC 1.5VA<br />

VS26SF22DF213A NO Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24V DC 1.2W<br />

VS26SF22DF218A NO Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115V AC 1.5VA<br />

VS26SF22DF513A NO Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24V DC 1.2W<br />

VS26SF22DF518A NO Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115V AC 1.5VA<br />

VS26SG11DF313A NO/NC Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Push only 24V DC 1.2W<br />

VS26SG11DF318A NO/NC Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Push only 115V AC 1.5VA<br />

VS26SG11DF213A NO/NC Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Push & turn 24V DC 1.2W<br />

VS26SG11DF218A NO/NC Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Push & turn 115V AC 1.5VA<br />

VS26SG11DF513A NO/NC Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Extended, push only 24V DC 1.2W<br />

VS26SG11DF518A NO/NC Sol/Spring Internal 44 to 145 1<br />

26” Hg to 145 (-0.9 to 10) Extended, push only 115V AC 1.5VA<br />

VS26SG22DF313A NO/NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 24V DC 1.2W<br />

VS26SG22DF318A NO/NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 115V AC 1.5VA<br />

VS26SG22DF213A NO/NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24V DC 1.2W<br />

VS26SG22DF218A NO/NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115V AC 1.5VA<br />

VS26SG22DF513A NO/NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24V DC 1.2W<br />

VS26SG22DF518A NO/NC Sol/Spring External 25 + (0.35 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115V AC 1.5VA<br />

NOTE: The supply ports for the 2x2/2 valves are port 3 & 5 on the end plate. Therefore the flow path is from port 3 to port 2 or port 5 to port 4. Port 1 is only used to supply internal<br />

pilot pressure. Therefore care must be used when selecting other valves to be used on the same manifold as the 2x2/2’s. You may be required to use isolation plugs in ports 3 & 5 to<br />

ensure proper operation.<br />

VAL-27<br />

<strong>VALVES</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!