54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

14<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

54 4 2 32<br />

50 30<br />

84 5 1 3 82<br />

Valve Manifolds VS18 Series<br />

Plug-in Mini ISO Valves<br />

2x2/2, 2x3/2, 5/2 and 5/3 valves, ISO 15407-2,<br />

2x2/2 Double solenoid actuated softseal valves flow = 0.56 Cv (550 l/min)<br />

1) Pilot air supply through port 1<br />

2) Pilot air supply through port 12/14<br />

Valve function designations<br />

NO = Normally open<br />

NC = Normally closed<br />

<strong>Norgren</strong>.com/usa – 303.794.2611 – help@amer.norgren.com<br />

Size 18 mm<br />

Model Function Actuation Pilot Pilot pressure Operating pressure Manual Voltage<br />

2 x 2/2 supply psi (bar) psi (bar) override<br />

VS18SE11DF313A NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push only 24 V DC 1.2 W<br />

VS18SE11DF318A NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push only 115 V AC 1.5 VA<br />

VS18SE11DF213A NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24 V DC 1.2 W<br />

VS18SE11DF218A NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115 V AC 1.5 VA<br />

VS18SE11DF513A NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24 V DC 1.2 W<br />

VS18SE11DF518A NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115 V AC 1.5 VA<br />

VS18SF11DF313A NO Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push only 24 V DC 1.2 W<br />

VS18SF11DF318A NO Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push only 115 V AC 1.5 VA<br />

VS18SF11DF213A NO Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24 V DC 1.2 W<br />

VS18SF11DF513A NO Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24 V DC 1.2 W<br />

VS18SF11DF518A NO Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115 V AC 1.5 VA<br />

VS18SF11DF218A NO Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115 V AC 1.5 VA<br />

VS18SE22DF313A NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 24 V DC 1.2 W<br />

VS18SE22DF318A NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 115 V AC 1.5 VA<br />

VS18SE22DF213A NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24 V DC 1.2 W<br />

VS18SE22DF218A NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115 V AC 1.5 V<br />

VS18SE22DF513A NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24 V DC 1.2 W<br />

VS18SE22DF518A NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115 V AC 1.5 VA<br />

VS18SF22DF313A NO Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 24 V DC 1.2 W<br />

VS18SF22DF318A NO Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 115 V AC 1.5 VA<br />

VS18SF22DF213A NO Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24 V DC 1.2 W<br />

VS18SF22DF218A NO Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115 V AC 1.5 VA<br />

VS18SF22DF513A NO Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24 V DC 1.2 W<br />

VS18SF22DF518A NO Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115 V AC 1.5 VA<br />

VS18SG11DF313A NO/NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push only 24 V DC 1.2 W<br />

VS18SG11DF318A NO/NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push only 115 V AC 1.5 VA<br />

VS18SG11DF213A NO/NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24 V DC 1.2 W<br />

VS18SG11DF218A NO/NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115 V AC 1.5 VA<br />

VS18SG11DF513A NO/NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24 V DC 1.2 W<br />

VS18SG11DF518A NO/NC Sol/spring Internal 36 to 145 (2.5 to 10) 1<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115 V AC 1.5 VA<br />

VS18SG22DF313A NO/NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 24 V DC 1.2 W<br />

VS18SG22DF318A NO/NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push only 115 V AC 1.5 VA<br />

VS18SG22DF213A NO/NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 24 V DC 1.2 W<br />

VS18SG22DF218A NO/NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Push & turn 115 V AC 1.5 VA<br />

VS18SG22DF513A NO/NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 24 V DC 1.2 W<br />

VS18SG22DF518A NO/NC Sol/spring External 25 + (0.5 x press. port 1) 2<br />

26" Hg to 145 (-0.9 to 10) Extended, push only 115 V AC 1.5 VA<br />

NOTE: The supply ports for the 2x2/2 valves are port 3 & 5 on the end plate. Therefore the flow path is from port 3 to port 2 or port 5 to port 4. Port 1 is only used to supply internal<br />

pilot pressure. Therefore care must be used when selecting other valves to be used on the same manifold as the 2x2/2’s. You may be required to use isolation plugs in ports 3 & 5 to<br />

ensure proper operation.<br />

VAL-3<br />

<strong>VALVES</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!