<strong>VALVES</strong><br />
Valve Manifolds VS26 Series<br />
Plug-in Mini ISO Valves<br />
2x2/2, 2x3/2, 5/2 and 5/3 valves, ISO 15407-2, Size 26 mm<br />
Fieldbus protocol: Interbus-S<br />
Connector: 2 x D-Sub 9-pin / M12 4-pin<br />
M 12<br />
0.85<br />
(21.5)<br />
VAL-44<br />
2.32<br />
(59)<br />
1.46<br />
(37)<br />
0.61<br />
(15.5)<br />
0.85<br />
(21.5)<br />
0.87<br />
(22)<br />
Fieldbus protocol: AS-Interface<br />
Connector: 1 x M12 / M12 4-pin<br />
M 12 M 12<br />
0.85<br />
(21.5)<br />
2.32<br />
(59)<br />
0.83<br />
(21)<br />
0.79<br />
(20)<br />
4<br />
3 1<br />
2<br />
4<br />
3 1<br />
2<br />
Fieldbus protocol: FD67 bus<br />
Connector: 2 x M12 6-pin (power connector integrated<br />
in bus connectors)<br />
M 12 M 12<br />
0.85<br />
(21.5)<br />
2.32<br />
(59)<br />
0.59<br />
(15)<br />
0.73<br />
(18.5)<br />
4<br />
3 1<br />
2<br />
4<br />
3 1<br />
2<br />
6 789<br />
Male<br />
1<br />
2<br />
3<br />
4<br />
5<br />
4<br />
4<br />
4<br />
Female<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Communication in Communication out<br />
Bus connector: M12 4-pin<br />
Pin no. Function Max.<br />
current<br />
1 AS-I 3)<br />
2 – –<br />
3 AS-I –<br />
4 – –<br />
Power connector: M12 4-pin<br />
Pin no. Function Tolerance Max.<br />
current<br />
1 +24 V DC +/-10% 4)<br />
2 - – –<br />
3 0 volts – –<br />
4 - – –<br />
<strong>Norgren</strong>.com/usa – 303.794.2611 – help@amer.norgren.com<br />
Male<br />
1<br />
Male<br />
1<br />
Male<br />
1<br />
6 789<br />
3<br />
2<br />
3<br />
2<br />
Communication<br />
in/out<br />
Male<br />
4<br />
5 3<br />
6<br />
1 2<br />
Communication<br />
in<br />
Female<br />
4<br />
3 5<br />
6<br />
2 1<br />
Communication<br />
out<br />
3<br />
2<br />
Bus connector: D-Sub 9-pin<br />
Pin no. Function Male Function Female<br />
1 DO DO<br />
2 DI DI<br />
3 OVI OVI<br />
4 – –<br />
5 – +5VI<br />
6 /DO /DO<br />
7 /DI /DI<br />
8 – –<br />
9 – RBST<br />
Power connector: M12 4-pin<br />
Pin no. Function Tolerance Max.<br />
current<br />
1 24 VB logic circuit supply +/-25% 300 mA<br />
2 24 VA valves +/-10% 1)<br />
3 0 volts – 2)<br />
4 Earth – –<br />
Bus connector: M12 6-pin<br />
Pin no. Function Tolerance Max.<br />
current<br />
1 24 V actuator supply ±10% 5)<br />
2 24 V sensor supply/internal supply ±25% 30 mA<br />
3 Ground – –<br />
4 Internal system connection – –<br />
5 Internal system connection – –<br />
6 Ground – –<br />
1) Imax = 10 mA + n*60 mA<br />
n = number of energized solenoids<br />
2) Imax = I VA + I VB<br />
3) Single slave: 40 mA<br />
Double slave: 75 mA<br />
4) Single slave:<br />
I max = 20 mA + n*60 mA<br />
Double slave:<br />
Imax = 35 mA + n*60 mA<br />
n = number of energized solenoids<br />
5) Imax = n*60 mA<br />
n = number of energized solenoids