<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> <strong>Central</strong><br />

<strong>Control</strong> <strong>Unit</strong> <strong>EWFS</strong> ® The <strong>Wisotronic</strong> encompasses four function blocks: Safety and comfort functions,<br />

5.3 Overview of the control<br />

system<br />

a timer switch and the possibility of manual operation. The following graphic<br />

explains the properties of the safety functions: When a safety function has been<br />

triggered, move commands are not executed - all the switches are open.<br />

Exception: An ice alert can be resetted temporarily. For further information please<br />

refer to Section 6.9.<br />

Safety functions<br />

Wind monitoring<br />

Rain monitoring<br />

Ice monitoring<br />

Move<br />

command<br />

Comfort functions<br />

Sun control<br />

Dawn/Dusk control<br />

Temperature control<br />

Comfort<br />

timer<br />

Timer switch<br />

Timer<br />

switch<br />

Manual operation<br />

Manual UP/DOWN<br />

Remote control UP/DOWN<br />

Function dial STOP<br />

Fig. 5-2:<br />

Safety functions active - switches are open, move commands are blocked.<br />

If no safety function has triggered, all the functions of the <strong>Wisotronic</strong> can be used<br />

to the full extent. This is illustrated in the following graphic: All the switches are<br />

closed. Exception: The comfort timer. For further information on this function<br />

please refer to Section 6.6.<br />

Safety functions<br />

Wind monitoring<br />

Rain monitoring<br />

Ice monitoring<br />

Move<br />

command<br />

Comfort functions<br />

Sun control<br />

Dawn/Dusk control<br />

Temperature control<br />

Comfort<br />

timer<br />

Timer switch<br />

Timer<br />

switch<br />

Manual operation<br />

Manual UP/DOWN<br />

Remote control UP/DOWN<br />

Function dial STOP<br />

Fig. 5-3:<br />

Comfort functions active: Switches are closed, move commands are enabled.<br />

22<br />

We reserve the right to carry out improvements<br />

932806A0•816757•7974k0•08.10.2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!