04.01.2015 Views

Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema

Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema

Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> <strong>Central</strong><br />

<strong>Control</strong> <strong>Unit</strong> <strong>EWFS</strong> ® This operating mode simply only triggers move commands when limits are<br />

6.3.6 Temperature control in the<br />

"Direct control" operating<br />

mode<br />

exceeded. Continue here if you have selected this operating mode. Otherwise<br />

skip this section. The following values can be changed:<br />

Operating mode:<br />

Direct control<br />

Temp.<br />

limit<br />

UP<br />

—24...<br />

+74°C<br />

Temp.<br />

limit<br />

DOWN<br />

—24...<br />

+74°C<br />

Fig. 6-10:<br />

Temperature control: Values which can be changed in the "Direct control"<br />

operating mode<br />

6.3.6.1 Temperature control<br />

limit "UP"<br />

The limit "UP" specifies the temperature from at the sunblind is to be moved up.<br />

Example: You want the sun to support the process of heating your conservatory<br />

on cold clear winter days. You can therefore specify for the control system from<br />

which temperature the sun protection is to be moved up in order to let the<br />

sunlight into the conservatory. The setting range is from –24°C to 74°C. If you do<br />

not want to evaluate the limit "UP", you can also set the value<br />

"0" (---) here. Proceed as follows in order to change the setting value:<br />

■<br />

Change to the temperature control menu as described above. Turn the<br />

function dial until the following display appears:<br />

Temperature<br />

limit UP<br />

22° C<br />

— + | }<br />

■ Change the setting values by using the buttons — + and then press the<br />

button |(save). If you want to exit the menu without saving the changes,<br />

press the } button twice consecutively. This completes the process.<br />