4 Planning<br />

Infeed • 200 V - 230 V AC, single-phase, two-phase (with grounded neutral (as<br />

symmetrical as possible) between the phases used<br />

• 50 Hz ± 1 Hz or 60 Hz ± 1 Hz<br />

Fusing • 2x 16 A slow-blowing, type C (1 (2)x phase; 1x neutral conductor (optional))<br />

4.5 Safety interface X11<br />

Description<br />

EMERGENCY STOP devices must be connected via safety interface X11 or<br />

linked together by means of higher-level controllers (e.g. PLC).<br />

Wiring Take the following points into consideration when wiring safety interface X11:<br />

• System concept<br />

• Safety concept<br />

Issued: 15.04.2014 Version: Spez <strong>KR</strong> <strong>C4</strong> <strong>compact</strong> V5<br />