<strong>ASDA</strong>-<strong>B2</strong><br />

Chapter 2 Installation and Storage<br />

Choose Suitable Motor Cable and Precautions<br />

Improper installation and choice of motor cable will affect the performance of EMI filter. Be<br />

sure to observe the following precautions when selecting motor cable.<br />

• Use the cable with shielding (double shielding is the best).<br />

• The shielding on both ends of the motor cable should be grounded with the minimum<br />

length and maximum contact area.<br />

• Remove any paint on metal saddle for good ground contact with the plate and shielding<br />

(Please refer to Figure 1 below).<br />

• The connection between the metal saddle and the shielding on both ends of the motor<br />

cable should be correct and well installed. Please refer to Figure 2 on next page for<br />

correct wiring method.<br />

Figure 1<br />

Saddle on both ends<br />

Saddle on one end<br />

Figure 2<br />