Table 4.1: The fit results <strong>for</strong> <strong>the</strong> 416 keV γ-ray M1 transition given in Figure 4.8<br />

Description Parameter Fixed/Free Value<br />

Half-life A 1 Fixed 1458 sec<br />

Primary Intensity A 2 Free 46921(98) counts/sec<br />

Polariz<strong>at</strong>ion Intensity A 3 Free −2816(170) counts/sec<br />

Depolariz<strong>at</strong>ion Time A 4 Free 16.7(5) sec<br />

Precession Frequency A 5 Free 1.9999(2) Hz<br />

Phase A 6 Free 4.71(2) rad<br />

1st Signal Intensity A 7 Free 8422(157) counts/sec<br />

2nd Signal Intensity A 8 Free 160(107) counts/sec<br />

3rd Signal Intensity A 9 Free 117(112) counts/sec<br />

4th Signal Intensity A 10 Free 264(120) counts/sec<br />

5th Signal Intensity A 11 Free −153(131) counts/sec<br />

6th Signal Intensity A 12 Free 216(148) counts/sec<br />

7th Signal Intensity A 13 Free −259(177) counts/sec<br />

10th Signal Intensity A 16 Free −683(366) counts/sec<br />

11th Signal Intensity A 17 Free −720(575) counts/sec<br />

where <strong>the</strong> average is given by,<br />

¯x =<br />

∑ n<br />

i=1 (x i/σ 2 i)<br />

∑ n<br />

i=1 (1/σ2 i ) , (4.5)<br />

and its variance is given by,<br />

σ 2¯x = 1<br />

∑ n<br />

i=1 (1/σ2 i ) . (4.6)<br />

The resulting sensitivity <strong>for</strong> 20different γ-raysis 1.65×10 −23 ecm <strong>for</strong>two anti-parallel<br />

GRIFFIN detectors and a spin-depolariz<strong>at</strong>ion time of 15 seconds. This accounts <strong>for</strong><br />

a total of approxim<strong>at</strong>ely 13 million counts in two anti-parallel GRIFFIN detectors.<br />

The RnEDM experiment is planned to run <strong>for</strong> a total of 100 days, which gives an<br />

estim<strong>at</strong>e of 1×10 12 photopeak counts in our GRIFFIN detectors [32], and is expected<br />

to achieve a spin-depolariz<strong>at</strong>ion time of <strong>at</strong> least 30 seconds. Section 4.2.3 calcul<strong>at</strong>es<br />

<strong>the</strong> achievable sensitivity <strong>for</strong> 100 days of counting.<br />