<strong>11</strong>.02 Exp<strong>and</strong>ing the Operator Interface (BE1)<br />

7 Configuring <strong>and</strong> Working Environment<br />

LAN1=File<br />

File Language-dependent file which contains the foreground language<br />

(1st language) of all configured texts.<br />

LAN2=File<br />

File Language-dependent file which contains the background language<br />

(2nd language) of all configured texts.<br />

If parameters LAN1/LAN2 are assigned, then the system looks for languagedependent<br />

texts in these files first before searching through the cycle alarm texts.<br />

The contents of the files specified by LAN1/LAN2 matches the format of the alarm<br />

texts (see Section 7.1 General information about configuring environment). File<br />

names can be freely assigned within the scope of the supplementary conditions<br />

stipulated in Section 1.4. The file extension is COM. These text files allow texts to<br />

be created directly in on-line operation which can then be displayed directly in<br />

screen forms created on-line.<br />

CHK_COMMON_COM=ram<br />

ram The control flag: specifies whether a COMMON.COM access<br />

check must be carried out.<br />

Possible values:<br />

0:<br />

A check for the existence of COMMON.COM on the<br />

RAMDRIVE of the MMC, HMI, HT6 is not carried out.<br />

COMMON.COM is read every time it is accessed by the NC.<br />

This setting is selected for test purposes while files are being<br />

set up in order to display any changes immediately.<br />

1:<br />

Check whether COMMON.COM is already stored on the<br />

MMC/HT6 RAMDRIVE. With this setting, files can be<br />

processed faster, but changes do not take effect until the<br />

system is restarted.<br />

© Siemens AG, <strong>2002</strong>. All rights reserved<br />

SINUMERIK 840D/840Di/810D HMI/MMC <strong>Installation</strong> <strong>and</strong> <strong>Start</strong>-<strong>Up</strong> <strong>Guide</strong> (IAM) – <strong>11</strong>.02 <strong>Edition</strong> BE1/7-157