<strong>11</strong>.02 <strong>Start</strong>ing <strong>Up</strong> HMI Advanced (IM4)<br />

7 <strong>Installation</strong> Variants / Data Backup<br />

3. Enter one of the passwords for levels 0-3.<br />

- System<br />

- Manufacturer<br />

- Servicer<br />

- Customer<br />

A warning appears advising caution: "Windows partition E: will be overwritten" <strong>and</strong>,<br />

following a second prompt, the restoration of partition E: is initiated.<br />

Once the partition E data has been restored, the "Restore finished" message will<br />

appear.<br />

The next time WinNT is booted, partition E: is checked by the test program<br />

CHKDSK.<br />

7.8 SINUMERIK desktop (Windows)<br />

The SINUMERIK desktop is designed to operate as a service mode, which can use<br />

Windows functions to start up the controller.<br />

It is used as the platform for network operation (e.g. for installing HMI system<br />

software), for setting the execution environment of HMI system software or for<br />

accompanying system measures such as authorizing SIMATIC STEP7, hard disk<br />

check, version check, etc.<br />

More detailed information can be found in 3.5, Basic functions of the SINUMERIK<br />

desktop.<br />

7.8.1 Networking<br />

The PCU has one network connection as st<strong>and</strong>ard.<br />

Windows NT<br />

Most of the network connection is already<br />

installed on delivery. Once you have<br />

connected the Ethernet cable, you need<br />

only enter the IP address of the PCU or<br />

select use of a DHCP server in order to<br />

set up a TCP/IP communication link.<br />

The entry is made under: <strong>Start</strong>→Settings<br />

→Control Panel→Network, Protocols tab,<br />

where the TCP/IP protocol properties can<br />

be selected.<br />

By this stage you must have already<br />

specified a unique computer name for the<br />

PCU across the entire network. You can<br />

enter the required name under <strong>Start</strong>→<br />

Settings→Control Panel→Network,<br />

Identification tab.<br />

Windows XP<br />

Connect the Ethernet cable for<br />

TCP/IP communication.<br />

The default setting is DHCP.<br />

The properties can be modified under<br />

<strong>Start</strong>→Settings→Network<br />

Connections→Local Area<br />

Connection→Properties.<br />

By this stage you must have already<br />

specified a unique computer name for<br />

the PCU across the entire network.<br />

You can enter the required name<br />

under <strong>Start</strong>→Settings→Control Panel<br />

→Computer Name tab, Change<br />

button.<br />

© Siemens AG, <strong>2002</strong>. All rights reserved<br />

SINUMERIK 840D/840Di/810D HMI/MMC <strong>Installation</strong> <strong>and</strong> <strong>Start</strong>-<strong>Up</strong> <strong>Guide</strong> (IAM) – <strong>11</strong>.02 <strong>Edition</strong> IM4/7-239