<strong>Start</strong>ing <strong>Up</strong> HMI Advanced (IM4) <strong>11</strong>.02<br />

5 Functions / Parameterization<br />

9661 CMM_ENABLE_CUSTOMER_M_CODES QV: FBSP<br />

Input of customer-specific M functions<br />

This MD is used to enable the number of input fields for customer-specific M functions:<br />

0 = No display fields for customer-specific M functions<br />

1 = 1 field for one customer-specific M function is displayed<br />

2 = 2 fields for two customer-specific M functions are displayed<br />

3 = 3 fields for two customer-specific M functions are displayed<br />

4 = 4 fields for two customer-specific M functions are displayed<br />

4 0 4<br />

9663 CMM_TOOL_DISPLAY_IN_DIAM QV: FBSP,<br />

FBT<br />

Radius/diameter display for tool<br />

This MD is used to specify how the tool should be displayed/entered:<br />

0 = Radius<br />

1 = Diameter<br />

1 0 1<br />

9672 CMM_FIXED_TOOL_PLACE QV : FBSP,<br />

FBT<br />

Fixed tool location coding<br />

This machine data is used to define the status of the tools:<br />

0 = Tools with variable tool location coding in magazine<br />

1 = Tools with fixed tool location coding in magazine<br />

Note for ST: On a turret, tools are always assigned a fixed location,<br />

i.e. the MD must be set to "1".<br />

Remark: If MD 9014: USE_CHANNEL_DISPLAY_DATA is set appropriately, MD 9672<br />

can be managed on a channel-specific basis in the NC.<br />

9673 CMM_TOOL_LOAD_STATION QV: FBSP,<br />

FBT<br />

Load station number<br />

This machine data can be used to define the load station via which the magazine<br />

is loaded <strong>and</strong> unloaded.<br />

1 = Load station 1<br />

2 = Load station 2<br />

Remark: If MD 9014: USE_CHANNEL_DISPLAY_DATA is set appropriately, MD 9673<br />

can be managed on a channel-specific basis in the NC.<br />

- 1 1 2<br />

9674 CMM_ENABLE_TOOL_MAGAZINE QV: FBSP,<br />

FBT<br />

- Display magazine list<br />

0 = Magazine list is not displayed<br />

1 = Magazine list is displayed<br />

1 0 1<br />

IM4/5-134<br />

© Siemens AG, <strong>2002</strong>. All rights reserved<br />