Bit 2, OFF3/ON3:<br />
Bit=0: Fast stop that uses deceleration time specified in DEC TIME4 (Enter OFF3 active state). When output<br />
frequency = 0 the drive output is disabled.<br />
Bit=1: Drive can be started if all other start conditions are fulfilled.<br />
Bit 3, Operation disabled/enabled<br />
Bit=0: Drive coast to stop (Enter Inhibit operation state).<br />
Bit=1: Drive can be started if all other start conditions are fulfilled.<br />
Bit 4, Ramp generator disabled/ Condition <strong>for</strong> operation<br />
Bit=0: Output frequency is set to 0. Inverter remains in Running state.<br />
Bit=1: Drive can be started if all other start conditions are fulfilled.<br />
Bit 5, Stop ramp generator/ Ramp generator enabled<br />
Bit=0: Actual output frequency is frozen. Changes to frequency setpoint has no affect.<br />
Bit=1: Drive can be started if all other start conditions are fulfilled.<br />
Bit 6, Setpoint disabled/enabled<br />
Bit=0: Normal stop that uses deceleration time specified in DEC TIME1.<br />
Bit=1: Drive can be started if all other start conditions are fulfilled.<br />
Bit 7, No function/ Fault acknowledge<br />
Bit=0: No fault acknowledge.<br />
Bit=1: Fault is acknowledged on positive edge, i.e. bit = 0 then 1 (Enter Switch-on inhibit state).<br />
Bit 10, Data invalid/ Data valid<br />
Bit=0: The control word and frequency setpoint (from <strong>PROFIBUS</strong>) are not activated.<br />
Bit=1: The control word and frequency setpoint (from <strong>PROFIBUS</strong>) are activated.<br />
Bit 11, No function/Reversing<br />
Bit=0: Drive is not reversing.<br />
Bit=1: Drive is reversing.<br />
USER MANUAL<br />
Revision 0.14<br />
2000-01-14<br />
HMS FIELDBUS SYSTEMS AB 24