PROFIBUS-DP OPTION OPC-G11S-PDP for ... - Fuji Electric America
PROFIBUS-DP OPTION OPC-G11S-PDP for ... - Fuji Electric America
PROFIBUS-DP OPTION OPC-G11S-PDP for ... - Fuji Electric America
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
8.3 Function data<br />
Code Name Uni<br />
t<br />
USER MANUAL<br />
Revision 0.14<br />
2000-01-14<br />
Variable range Min. unit Read/Write<br />
S08 Acceleration time F07 s 0.1–3600.0 0.1 R/W<br />
S09 Deceleration time F08 s 0.1–3600.0 0.1 R/W<br />
S10 Torque limit level 1 (Driving ) F40 % 20.00–200.00<br />
(P11S : 20.00–150.00), 999<br />
S11 Torque limit level 2 (Braking ) F41 % 0.00, 20.00–200.00<br />
(P11S : 20.00–150.00), 999<br />
1.00 R/W<br />
1.00 R/W<br />
Note:<br />
1) The writing to out of the range is treated as out of range error.<br />
2) The acceleration and deceleration time S08 and S09 are assigned to "F07: Acceleration time‚P" and<br />
"F08: Deceleration time 1" respectively.<br />
3) The torque limit level 1 and 2 of S10 and S11 are assigned to "F40: Torque limit 1 (Driving )" and<br />
"F41: Torque limit 1 (Braking )" respectively<br />
HMS FIELDBUS SYSTEMS AB 40