The Electronic Load
The Electronic Load
The Electronic Load
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>The</strong> <strong>Electronic</strong> <strong>Load</strong><br />
Interface overview<br />
RS-232<br />
O<br />
USB<br />
O<br />
GPIB<br />
O<br />
LAN<br />
O<br />
System bus<br />
O<br />
Analog<br />
X<br />
Analog isolated<br />
O<br />
X Standard O Option / not available<br />
Specially designed for testing fuel cells<br />
Currents up to 2,250 A<br />
Power 1,000 W ... 6,000 W<br />
Full current at 150 mV input voltage<br />
Current, voltage, resistance, power mode<br />
Dynamic loads<br />
SCPI programming with measurement function<br />
Model<br />
ZSLV1002 ZSLV1502 ZSLV2002 ZSLV4002 ZSLV6002<br />
(order number)<br />
Voltage 20 V 20 V 20 V 20 V 20 V<br />
Current 220 A 500 A 750 A 1,500 A 2,250 A<br />
Vmin @ Imax 150 mV 150 mV 175 mV 200 mV 200 mV<br />
Continuous power 1,000 W 1,500 W 2,000 W 4,000 W 6,000 W<br />
Current setting<br />
Resistance setting<br />
Power setting<br />
0 ... 73 A<br />
0 ... 220 A<br />
2 mΩ ... 3 Ω<br />
(max. 73 A)<br />
0.7 mΩ ... 1 Ω<br />
(max. 220 A)<br />
0 ... 333 W<br />
0 ... 1,000 W<br />
<strong>Electronic</strong> <strong>Load</strong>s, ZSLV series<br />
Low Voltage<br />
1,000 W ... 6,000 W DC Low Voltage<br />
0 ... 166 A<br />
0 ... 500 A<br />
0.9 mΩ ... 1.33 Ω<br />
(max. 166 A)<br />
0.3 mΩ ... 0.44 Ω<br />
(max. 500 A)<br />
0 ... 500 W<br />
0 ... 1,500 W<br />
Full electronic protection<br />
Analog measurement outputs for voltage and current<br />
Analog control input<br />
0 ... 250 A<br />
0 ... 750 A<br />
0.7 mΩ ... 0.9 Ω<br />
(max. 250 A)<br />
0.23 mΩ ... 0.3 Ω<br />
(max. 750 A)<br />
0 ... 666 W<br />
0 ... 2,000 W<br />
0 ... 500 A<br />
0 ... 1,500 A<br />
0.4 mΩ ... 0.45 Ω<br />
(max. 500 A)<br />
0.13 mΩ ... 0.15 Ω<br />
(max. 1,500 A)<br />
0 ... 1,333 W<br />
0 ... 4,000 W<br />
0 ... 750 A<br />
0 ... 2,250 A<br />
0.27 mΩ ... 0.26 Ω<br />
(max. 750 A)<br />
0.09 mΩ ... 0.087 Ω<br />
(max. 2,250 A)<br />
0 ... 2,000 W<br />
0 ... 6,000 W<br />
Rise/fall time 1) 500 µs 500 µs 600 µs 600 µs 750 µs<br />
<strong>Load</strong> connections 2) FK50 FK50 FK50 FK50 FK50<br />
Power consumption 90 VA 110 VA 120 VA 150 VA 260 VA<br />
Noise max. 3) 58 dB(A) 58 dB(A) 62 dB(A) 64 dB(A) 65 dB(A)<br />
Weight 34 kg 39 kg 48 kg 73 kg 98 kg<br />
Housing 4) 19“ - 5 HU 19“ - 5 HU 19“ - 5 HU 19“ - 8 HU 19“ - 11 HU<br />
1) Rise and fall times are defined as<br />
10% ... 90% and 90% ... 10% of the<br />
maximum current.<br />
(current mode FAST, tolerance ±20%)<br />
ZSLV1502<br />
2) FK50: flat copper rail 50x10 mm with<br />
M12 bolt<br />
3) Measured on the front from distance<br />
of 1 m<br />
4) 1 HU = 44.45 mm<br />
Application Notes ZS PL H&H<br />
ZSLC<br />
Water-cooled<br />
ZSLV<br />
Low Voltage<br />
PMLI<br />
Multi-channel<br />
ZSAC<br />
AC<br />
NL<br />
Source-Sink<br />
Accessories<br />
Software<br />
GTC<br />
29