<strong>The</strong> <strong>Electronic</strong> <strong>Load</strong><br />

Option MPP Tracking (ZS13)<br />

<strong>The</strong> ZS series <strong>Electronic</strong> <strong>Load</strong>s<br />

can be upgraded with the ZS13<br />

option to perform MPP tracking<br />

(Maximum Power Point<br />

Tracking).<br />

MPP tracking is used with solar<br />

panels to determine the panel's<br />

maximum possible power. This<br />

operating point (MPP) is derived<br />

from the characteristic of a solar<br />

panel. <strong>The</strong> MPP function of the<br />

electronic load searches for this<br />

point and tracks it, even when<br />

Input of system parameters<br />

<strong>The</strong> extent to which the<br />

electronic load controls via the<br />

MPP can be determined by<br />

inputting the system parameter<br />

no. 53 "Delta_P_min".<br />

<strong>The</strong> electronic load also needs<br />

details about the values in the<br />

table below:<br />

the sun's radiation fluctuates.<br />

Functional principle<br />

For correct use of the MPP<br />

function of the electronic load it<br />

is necessary to understand the<br />

functional principle.<br />

<strong>The</strong> electronic load operates in<br />

MPP mode in constant voltage<br />

mode.<br />

If the function is activated, the<br />

load starts with a higher voltage<br />

than the max. voltage of the<br />

<strong>The</strong>se parameters are needed<br />

for the electronic load to set the<br />

suitable current range and find<br />

the MPP point as fast as<br />

possible.<br />

<strong>The</strong> parameters are saved<br />

permanently to the device and<br />

are available after switching the<br />

mains power off and on again.<br />

Panel data Abbreviation Parameter<br />

Rated power „Pmax“ 48<br />

Open circuit voltage „VOC“ 49<br />

Max. short circuit current „ISC“ 10<br />

Voltage in MPP „VPM“ 51<br />

Current in MPP „IPM“ 52<br />

Power range „Delta_P_min“ 53<br />

H&H Application Note #10<br />

MPP tracking with ZS series <strong>Electronic</strong> <strong>Load</strong>s<br />

solar panel and reduces the<br />

voltage.<br />

When the specified voltage on<br />

the electronic load is less than<br />

the actual voltage of the solar<br />

panel, current starts to flow.<br />

<strong>The</strong> electronic load continually<br />

measures voltage and current<br />

and calculates the recorded<br />

power.<br />

While the power increases the<br />

direction of the voltage change<br />

is retained. If the power falls<br />

(when the settings exceed the<br />

maximum power) the direction<br />

of the voltage change reverses<br />

so that the power rises again.<br />

Application Notes ZS PL H&H<br />

ZSLC<br />

Water-cooled<br />

ZSLV<br />

Low Voltage<br />

GTC<br />

PMLI<br />

Multi-channel<br />

ZSAC<br />

AC<br />

NL<br />

Source-Sink<br />

Accessories<br />

Software<br />

69

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!