The Electronic Load
The Electronic Load
The Electronic Load
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>The</strong> <strong>Electronic</strong> <strong>Load</strong><br />
Option MPP Tracking (ZS13)<br />
<strong>The</strong> ZS series <strong>Electronic</strong> <strong>Load</strong>s<br />
can be upgraded with the ZS13<br />
option to perform MPP tracking<br />
(Maximum Power Point<br />
Tracking).<br />
MPP tracking is used with solar<br />
panels to determine the panel's<br />
maximum possible power. This<br />
operating point (MPP) is derived<br />
from the characteristic of a solar<br />
panel. <strong>The</strong> MPP function of the<br />
electronic load searches for this<br />
point and tracks it, even when<br />
Input of system parameters<br />
<strong>The</strong> extent to which the<br />
electronic load controls via the<br />
MPP can be determined by<br />
inputting the system parameter<br />
no. 53 "Delta_P_min".<br />
<strong>The</strong> electronic load also needs<br />
details about the values in the<br />
table below:<br />
the sun's radiation fluctuates.<br />
Functional principle<br />
For correct use of the MPP<br />
function of the electronic load it<br />
is necessary to understand the<br />
functional principle.<br />
<strong>The</strong> electronic load operates in<br />
MPP mode in constant voltage<br />
mode.<br />
If the function is activated, the<br />
load starts with a higher voltage<br />
than the max. voltage of the<br />
<strong>The</strong>se parameters are needed<br />
for the electronic load to set the<br />
suitable current range and find<br />
the MPP point as fast as<br />
possible.<br />
<strong>The</strong> parameters are saved<br />
permanently to the device and<br />
are available after switching the<br />
mains power off and on again.<br />
Panel data Abbreviation Parameter<br />
Rated power „Pmax“ 48<br />
Open circuit voltage „VOC“ 49<br />
Max. short circuit current „ISC“ 10<br />
Voltage in MPP „VPM“ 51<br />
Current in MPP „IPM“ 52<br />
Power range „Delta_P_min“ 53<br />
H&H Application Note #10<br />
MPP tracking with ZS series <strong>Electronic</strong> <strong>Load</strong>s<br />
solar panel and reduces the<br />
voltage.<br />
When the specified voltage on<br />
the electronic load is less than<br />
the actual voltage of the solar<br />
panel, current starts to flow.<br />
<strong>The</strong> electronic load continually<br />
measures voltage and current<br />
and calculates the recorded<br />
power.<br />
While the power increases the<br />
direction of the voltage change<br />
is retained. If the power falls<br />
(when the settings exceed the<br />
maximum power) the direction<br />
of the voltage change reverses<br />
so that the power rises again.<br />
Application Notes ZS PL H&H<br />
ZSLC<br />
Water-cooled<br />
ZSLV<br />
Low Voltage<br />
GTC<br />
PMLI<br />
Multi-channel<br />
ZSAC<br />
AC<br />
NL<br />
Source-Sink<br />
Accessories<br />
Software<br />
69