THREE SEQUENCE WASH<br />

MODELS: MP30C, MP30H<br />

CAPACITY<br />

One ¾” (19 mm) to 1.5” (38 mm) hot water inlet and one ¾”<br />

(19 mm) to 1.5” (38 mm) hot water outlet connection piped to<br />

three ¾” (19 mm)to 1.5” (38 mm) hot water connections to<br />

three groups of hoods for washing up to 150 ft. (45 m) of<br />

ventilators.<br />

When the fan selector switch has been rotated to the “OFF”<br />

position, after a 60 second time delay, the blue “WASH #1”<br />

pilot, the detergent pump, and the hot water solenoid #1 are<br />

energized.<br />

MP10C & MP10H Water Wash Panel<br />

Figure 9<br />

Three sequence control panels have remote hot water solenoid valves. A 120/1/60 signal is supplied to each hot water solenoid<br />

valve through terminals H1, H2, H3, and 4 in the control panel.<br />

Terminals<br />

Component<br />

H1 & 4 Hot water solenoid valve #1<br />

H2 & 4 Hot water solenoid valve #2<br />

H3 & 4 Hot water solenoid valve #3<br />

Setting the length of the 1st wash<br />

MP30, AP30 Panels<br />

L N I1 I2 I3 I4 I5 I6 I7 I8 L N I1 I2 I3 I4<br />

SERVICE<br />

FILTERS<br />

WITHIN<br />

4 HOURS<br />

LOGO!<br />

Q1 Q2 Q3<br />

1 2 1 2 1 2<br />

ESC<br />

Q4<br />

OK<br />

AUX!<br />

1 2<br />

1 2 1 2<br />

Logo controller located in the water<br />

wash panel electrical section<br />

1<br />

Q1<br />

Q3<br />

RUN/STOP<br />

2<br />

Q2<br />

1 2<br />

Q4<br />

Su 06:16<br />

01. 06. 03<br />

>Stop<br />

Set Parma<br />

Set Clock<br />

Prg Name<br />

Stop<br />

>Set Parma<br />

Set Clock<br />

Prg Name<br />

B01: T<br />

T = 01:30m<br />

Ta = 01:30m<br />

B01: T<br />

T = 1:30m<br />

Ta = 01:30m<br />

B01: T<br />

T = 01:30m<br />

Ta = 02:30m<br />

B01: T<br />

T = 02:00m<br />

Ta = 02:00m<br />

Su 06:16<br />

01. 06. 03<br />

1. Press<br />

2. Press once.<br />

3. Press<br />

OK<br />

4. Press<br />

ESC<br />

until the B01 timer appears. This is the 1st wash timer.<br />

5. To change the 1st wash time press<br />

6. The first two digits are minutes and the two digits to the right are seconds.<br />

Press to change the wash length in minutes. Press to move to the<br />

the wash time in seconds. Press to change the seconds.<br />

7. Press OK if the wash time is correct.<br />

12. Press ESC and ESC to return to the operating screen.<br />

OK<br />