THREE SEQUENCE WASH<br />
MODELS: MP30C, MP30H<br />
CAPACITY<br />
One ¾” (19 mm) to 1.5” (38 mm) hot water inlet and one ¾”<br />
(19 mm) to 1.5” (38 mm) hot water outlet connection piped to<br />
three ¾” (19 mm)to 1.5” (38 mm) hot water connections to<br />
three groups of hoods for washing up to 150 ft. (45 m) of<br />
ventilators.<br />
When the fan selector switch has been rotated to the “OFF”<br />
position, after a 60 second time delay, the blue “WASH #1”<br />
pilot, the detergent pump, and the hot water solenoid #1 are<br />
energized.<br />
MP10C & MP10H Water Wash Panel<br />
Figure 9<br />
Three sequence control panels have remote hot water solenoid valves. A 120/1/60 signal is supplied to each hot water solenoid<br />
valve through terminals H1, H2, H3, and 4 in the control panel.<br />
Terminals<br />
Component<br />
H1 & 4 Hot water solenoid valve #1<br />
H2 & 4 Hot water solenoid valve #2<br />
H3 & 4 Hot water solenoid valve #3<br />
Setting the length of the 1st wash<br />
MP30, AP30 Panels<br />
L N I1 I2 I3 I4 I5 I6 I7 I8 L N I1 I2 I3 I4<br />
SERVICE<br />
FILTERS<br />
WITHIN<br />
4 HOURS<br />
LOGO!<br />
Q1 Q2 Q3<br />
1 2 1 2 1 2<br />
ESC<br />
Q4<br />
OK<br />
AUX!<br />
1 2<br />
1 2 1 2<br />
Logo controller located in the water<br />
wash panel electrical section<br />
1<br />
Q1<br />
Q3<br />
RUN/STOP<br />
2<br />
Q2<br />
1 2<br />
Q4<br />
Su 06:16<br />
01. 06. 03<br />
>Stop<br />
Set Parma<br />
Set Clock<br />
Prg Name<br />
Stop<br />
>Set Parma<br />
Set Clock<br />
Prg Name<br />
B01: T<br />
T = 01:30m<br />
Ta = 01:30m<br />
B01: T<br />
T = 1:30m<br />
Ta = 01:30m<br />
B01: T<br />
T = 01:30m<br />
Ta = 02:30m<br />
B01: T<br />
T = 02:00m<br />
Ta = 02:00m<br />
Su 06:16<br />
01. 06. 03<br />
1. Press<br />
2. Press once.<br />
3. Press<br />
OK<br />
4. Press<br />
ESC<br />
until the B01 timer appears. This is the 1st wash timer.<br />
5. To change the 1st wash time press<br />
6. The first two digits are minutes and the two digits to the right are seconds.<br />
Press to change the wash length in minutes. Press to move to the<br />
the wash time in seconds. Press to change the seconds.<br />
7. Press OK if the wash time is correct.<br />
12. Press ESC and ESC to return to the operating screen.<br />
OK<br />