DETERGENT PUMP<br />
Replacing the Diaphragm<br />
Figure 52<br />
1. Remove cover from pump head, exposing four screws.<br />
2. Unscrew all four screws from pump head.<br />
3. Be sure the drive assembly is in full stroke, rotate knob assembly until yoke is in a forward position. This will take pressure off<br />
diaphragm.<br />
4. Using your fingers, unscrew the diaphragm counter clockwise.<br />
5. When replacing old diaphragm with new, check to make sure the size of the spacers is the same (located under the nut on the<br />
diaphragm).<br />
6. When reattaching the pump head, tighten the four screws a little at a time. Do not over squeeze the diaphragm.<br />
Figure 53<br />
NO Description: Part Number<br />
1 Top valve fitting. C-537-6V<br />
2 Bottom valve fitting. C-538-6V<br />
3 Poly tubing/opaque 5’. C-335-6-5<br />
4 PVC tubing/clear 5’. C-334-6<br />
5 T.I. Anti siphon valve fitting (optional) T140-6V<br />
6 Threaded Anti siphon valve, ¼ & ½” NPT C-395HD-6V<br />
Threaded Anti siphon valve, ¼” NPT<br />
C-395-6V<br />
7 Food valve/screen. C-340N-6V<br />
8 Ceramic Weight C-346<br />
_____________________________________________________________________________________________<br />
<strong>Spring</strong> <strong>Air</strong> <strong>Systems</strong> Water Wash Ventilator Maintenance <strong>Manual</strong> 2010 Update<br />
48