FIREPLACE PREPARATION<br />

BEFORE FULLY INSTALLING THE UNIT:<br />

• Turn OFF the <strong>gas</strong> supply to the fireplace <strong>or</strong> firebox.<br />

• Seal any fresh air vents and/<strong>or</strong> ash clean-out do<strong>or</strong>s located on the flo<strong>or</strong> <strong>or</strong> wall of the fireplace. If left unsealed, drafting<br />

may cause pilot outage <strong>or</strong> sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.<br />

WARNING<br />

Bef<strong>or</strong>e installing in a solid fuel burning<br />

fireplace, The chimney flue and firebox<br />

must be cleaned of soot, creosote,<br />

ashes and loose paint by a qualified<br />

chimney cleaner.<br />

INSTALLING VENTED APPLICATIONS<br />

Manual, milli-volt and Hi/Lo controlled <strong>gas</strong> <strong>log</strong>s may be installed as a <strong>vented</strong> dec<strong>or</strong>ative <strong>log</strong> set in compliance with ANSI<br />

Z21.60 and National Fuel Gas Code, Section 6.6. Since, the <strong>gas</strong> <strong>log</strong>s are operated with the damper open, non-combustible<br />

material and minimum mantel requirements do not apply.<br />

WARNING<br />

This appliance is f<strong>or</strong> installation only in a solid fuel burning fireplace (masonry fireplace<br />

<strong>or</strong> manufactured fireplace) with a w<strong>or</strong>king flue and constructed of noncombustible<br />

material.<br />

Exception: DO NOT install this appliance in a fact<strong>or</strong>y-built fireplace that includes<br />

instructions stating that it has not been tested <strong>or</strong> should not be used with <strong>un<strong>vented</strong></strong><br />

<strong>gas</strong> <strong>log</strong>s. This <strong>log</strong> set may be installed as a <strong>vented</strong> <strong>log</strong> set.<br />

BEFORE INSTALLING THE APPLIANCE:<br />

• Turn off <strong>gas</strong> supply to fireplace <strong>or</strong> firebox.<br />

• Have the fireplace flo<strong>or</strong> and chimney professionally cleaned to remove ashes, soot, creosote <strong>or</strong> other obstructions.<br />

Have this cleaning perf<strong>or</strong>med annually after installation.<br />

• Seal any fresh air vents <strong>or</strong> ash clean-out do<strong>or</strong>s located on flo<strong>or</strong> <strong>or</strong> wall of fireplace. If not, drafting may cause pilot<br />

outage <strong>or</strong> sooting. Use a heat-resistant sealant.<br />

Install and operate the appliance as directed in this manual.<br />

DAMPER STOP INSTALLATION:<br />

A damper stop must be provided with the unit. Contact<br />

your dealer to obtain one. The damper stop must be<br />

installed as shown in Figure 13 to prevent full closure<br />

of the fireplace damper blade and provide a minimum<br />

29 square inch flue opening.<br />

<br />

<br />

Figure 13 - Damper Stop Installation.<br />

(See WARNING at top of next page.)<br />