FIREPLACE PREPARATION<br />
BEFORE FULLY INSTALLING THE UNIT:<br />
• Turn OFF the <strong>gas</strong> supply to the fireplace <strong>or</strong> firebox.<br />
• Seal any fresh air vents and/<strong>or</strong> ash clean-out do<strong>or</strong>s located on the flo<strong>or</strong> <strong>or</strong> wall of the fireplace. If left unsealed, drafting<br />
may cause pilot outage <strong>or</strong> sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.<br />
WARNING<br />
Bef<strong>or</strong>e installing in a solid fuel burning<br />
fireplace, The chimney flue and firebox<br />
must be cleaned of soot, creosote,<br />
ashes and loose paint by a qualified<br />
chimney cleaner.<br />
INSTALLING VENTED APPLICATIONS<br />
Manual, milli-volt and Hi/Lo controlled <strong>gas</strong> <strong>log</strong>s may be installed as a <strong>vented</strong> dec<strong>or</strong>ative <strong>log</strong> set in compliance with ANSI<br />
Z21.60 and National Fuel Gas Code, Section 6.6. Since, the <strong>gas</strong> <strong>log</strong>s are operated with the damper open, non-combustible<br />
material and minimum mantel requirements do not apply.<br />
WARNING<br />
This appliance is f<strong>or</strong> installation only in a solid fuel burning fireplace (masonry fireplace<br />
<strong>or</strong> manufactured fireplace) with a w<strong>or</strong>king flue and constructed of noncombustible<br />
material.<br />
Exception: DO NOT install this appliance in a fact<strong>or</strong>y-built fireplace that includes<br />
instructions stating that it has not been tested <strong>or</strong> should not be used with <strong>un<strong>vented</strong></strong><br />
<strong>gas</strong> <strong>log</strong>s. This <strong>log</strong> set may be installed as a <strong>vented</strong> <strong>log</strong> set.<br />
BEFORE INSTALLING THE APPLIANCE:<br />
• Turn off <strong>gas</strong> supply to fireplace <strong>or</strong> firebox.<br />
• Have the fireplace flo<strong>or</strong> and chimney professionally cleaned to remove ashes, soot, creosote <strong>or</strong> other obstructions.<br />
Have this cleaning perf<strong>or</strong>med annually after installation.<br />
• Seal any fresh air vents <strong>or</strong> ash clean-out do<strong>or</strong>s located on flo<strong>or</strong> <strong>or</strong> wall of fireplace. If not, drafting may cause pilot<br />
outage <strong>or</strong> sooting. Use a heat-resistant sealant.<br />
Install and operate the appliance as directed in this manual.<br />
DAMPER STOP INSTALLATION:<br />
A damper stop must be provided with the unit. Contact<br />
your dealer to obtain one. The damper stop must be<br />
installed as shown in Figure 13 to prevent full closure<br />
of the fireplace damper blade and provide a minimum<br />
29 square inch flue opening.<br />
<br />
<br />
Figure 13 - Damper Stop Installation.<br />
(See WARNING at top of next page.)<br />
18 44D0060