A-<strong>dec</strong> <strong>500</strong> <strong>12</strong> O’Clock <strong>System</strong> Installation Guide<br />
Handpiece Control Adjustments<br />
Water Coolant Flow<br />
The water coolant flow control adjusts the<br />
water to all handpieces. Use the adjustment<br />
key or a hex key to complete the adjustment:<br />
1. Lift the handpiece from the holder.<br />
2. Locate the water coolant flow controls.<br />
See Figure 20.<br />
3. Turn the water coolant on.<br />
4. Insert an adjustment key or hex key into<br />
the water coolant flow control for the<br />
handpiece being adjusted.<br />
5. Press the foot control to activate<br />
the handpiece.<br />
6. Adjust the water coolant flow to fit the<br />
user’s needs (normally 1-2 drops per<br />
second).<br />
• Turn the adjustment key to the right to<br />
<strong>dec</strong>rease flow.<br />
• Turn the adjustment key to the left to<br />
increase flow.<br />
Figure 20. Adjust Water and Air Coolant Flow<br />
Air Coolant Flow<br />
Adjustments<br />
Water Coolant<br />
Flow Adjustments<br />
NOTE Typically, one of the<br />
handpiece positions is air only.<br />
A-<strong>dec</strong> customizes handpiece<br />
configuration at time of order.<br />
Air Coolant Flow<br />
The air coolant flow control adjusts the air<br />
coolant flow to all handpieces. Use the<br />
adjustment key or a hex key to complete the<br />
adjustment:<br />
NOTE Adjusting the air coolant for<br />
one handpiece sets it for all of the<br />
positions.<br />
1. Lift the handpiece from the holder.<br />
2. Locate the air coolant control. See<br />
Figure 20.<br />
3. Use the Deluxe Touchpad to verify that<br />
the air coolant is on.<br />
10 86.0466.00 Rev D