Technical leaflet<br />
Fractional HP Condensing Units<br />
Compressor Model Designation<br />
1 2 3 4 5 6 7<br />
Compressor<br />
Design<br />
P<br />
Protector Location Optimization Level Compressor Size Application Range Refrigerant Code Letter<br />
for Starting<br />
Internal External<br />
Characteristics<br />
Standard-High Capacity at Displace-<br />
PTC Relay<br />
PTC Relay VSD*<br />
Rating Point ment<br />
“LST” “HST” (cc)<br />
Always<br />
Semidirect<br />
Intake<br />
E a) 20, 30, 35, 50<br />
CL=LBP<br />
CN=LBP<br />
R404A/R507<br />
R290<br />
Generation<br />
T<br />
N<br />
F<br />
L<br />
R<br />
T F LV<br />
Blank<br />
E b)<br />
S<br />
Always Semidirect<br />
Intake<br />
2.5, 3, 4, 4.5,<br />
4.8, 5, 5.7, 6,<br />
6.5, 7, 7.5, 8,<br />
8.7, 9, 10<br />
Y a) X a)<br />
5.2, 5.5, 5.7,<br />
6, 6.5, 7, 7.3,<br />
8.4, 8.8, 9,<br />
10, 11, 13, 15<br />
6, 7.5, 8.5,<br />
10, 11<br />
DL=HBP<br />
F=LBP/(MBP)<br />
FT=LBP Tropical<br />
G=LBP/MBP/HBP<br />
GH=Heat Pumps<br />
GHH=Heat Pumps (opt.)<br />
K=LBP/(MBP)<br />
KT=LBP/(MBP) Tropical<br />
MF=MBP<br />
R404/R507<br />
R134a<br />
R134a<br />
R134a<br />
R134a<br />
R134a<br />
R600a<br />
R600a<br />
R134a<br />
Blank-<br />
Universal<br />
(Principal Rule)<br />
K=LST<br />
Characteristics<br />
(Capillary Tube)<br />
X=HST<br />
Characteristics<br />
(Expansion Valve)<br />
Blank-<br />
First Generation<br />
2-<br />
Second Generation<br />
3-<br />
<strong>Third</strong> Generation<br />
etc.<br />
MK=MBP<br />
R600a<br />
S C C<br />
10, 12, 15,<br />
18, 21<br />
ML=MBP<br />
R404A/R507<br />
*Variable Speed Drive Blank = Standard a) = RC Compulsory<br />
E = Semi-Direct Intake b) = RC Optional<br />
Y = High Energy-Optimized<br />
X = High Energy-Optimized<br />
MN=MBP<br />
R290<br />
Serial number and date<br />
code information<br />
Danfoss does not serialize the compressors but<br />
we do put a date stamp on them. Stamped into<br />
the shell above or just to the right of the paper<br />
label are two lines of data. The first line states<br />
the model designation and the code number,<br />
e.g. L-4CL-2071:<br />
L = last letter (or last two letters) of the<br />
compressor type,<br />
4CL = nominal displacement,<br />
2071 = 4 last digits in the code no.<br />
The second line contains the manufacturing<br />
place, the date of manufacture and an internal<br />
code,<br />
e.g., F-202E2207:<br />
F = Manufacturing place (F = Germany, AL =<br />
Slovenia, AM = Mexico),<br />
20 = week 20,<br />
2 = 2002,<br />
E = Friday (A = Monday, etc.),<br />
220 = nominal voltage,<br />
7 = internal Danfoss Code.<br />
Beginning in 2002 Danfoss started to introduce<br />
a new coding consisting of two lines,<br />
e.g., H47117:<br />
043C12A.<br />
First line:<br />
H4711 = 5 last digits in the code no.,<br />
7 = internal Danfoss Code.<br />
Second line:<br />
04 = week 04,<br />
3 = 2003,<br />
C = Wednesday (A = Monday, etc.),<br />
12 = Internal Danfoss Code,<br />
A = Manufacturing place (A-G = Germany, K-N =<br />
Slovenia, R-S = Mexico).<br />