27.01.2015 Views

Condensed Catalog Featuring R410A Products Third Edition

Condensed Catalog Featuring R410A Products Third Edition

Condensed Catalog Featuring R410A Products Third Edition

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical leaflet<br />

Fractional HP Condensing Units<br />

Compressor Model Designation<br />

1 2 3 4 5 6 7<br />

Compressor<br />

Design<br />

P<br />

Protector Location Optimization Level Compressor Size Application Range Refrigerant Code Letter<br />

for Starting<br />

Internal External<br />

Characteristics<br />

Standard-High Capacity at Displace-<br />

PTC Relay<br />

PTC Relay VSD*<br />

Rating Point ment<br />

“LST” “HST” (cc)<br />

Always<br />

Semidirect<br />

Intake<br />

E a) 20, 30, 35, 50<br />

CL=LBP<br />

CN=LBP<br />

R404A/R507<br />

R290<br />

Generation<br />

T<br />

N<br />

F<br />

L<br />

R<br />

T F LV<br />

Blank<br />

E b)<br />

S<br />

Always Semidirect<br />

Intake<br />

2.5, 3, 4, 4.5,<br />

4.8, 5, 5.7, 6,<br />

6.5, 7, 7.5, 8,<br />

8.7, 9, 10<br />

Y a) X a)<br />

5.2, 5.5, 5.7,<br />

6, 6.5, 7, 7.3,<br />

8.4, 8.8, 9,<br />

10, 11, 13, 15<br />

6, 7.5, 8.5,<br />

10, 11<br />

DL=HBP<br />

F=LBP/(MBP)<br />

FT=LBP Tropical<br />

G=LBP/MBP/HBP<br />

GH=Heat Pumps<br />

GHH=Heat Pumps (opt.)<br />

K=LBP/(MBP)<br />

KT=LBP/(MBP) Tropical<br />

MF=MBP<br />

R404/R507<br />

R134a<br />

R134a<br />

R134a<br />

R134a<br />

R134a<br />

R600a<br />

R600a<br />

R134a<br />

Blank-<br />

Universal<br />

(Principal Rule)<br />

K=LST<br />

Characteristics<br />

(Capillary Tube)<br />

X=HST<br />

Characteristics<br />

(Expansion Valve)<br />

Blank-<br />

First Generation<br />

2-<br />

Second Generation<br />

3-<br />

<strong>Third</strong> Generation<br />

etc.<br />

MK=MBP<br />

R600a<br />

S C C<br />

10, 12, 15,<br />

18, 21<br />

ML=MBP<br />

R404A/R507<br />

*Variable Speed Drive Blank = Standard a) = RC Compulsory<br />

E = Semi-Direct Intake b) = RC Optional<br />

Y = High Energy-Optimized<br />

X = High Energy-Optimized<br />

MN=MBP<br />

R290<br />

Serial number and date<br />

code information<br />

Danfoss does not serialize the compressors but<br />

we do put a date stamp on them. Stamped into<br />

the shell above or just to the right of the paper<br />

label are two lines of data. The first line states<br />

the model designation and the code number,<br />

e.g. L-4CL-2071:<br />

L = last letter (or last two letters) of the<br />

compressor type,<br />

4CL = nominal displacement,<br />

2071 = 4 last digits in the code no.<br />

The second line contains the manufacturing<br />

place, the date of manufacture and an internal<br />

code,<br />

e.g., F-202E2207:<br />

F = Manufacturing place (F = Germany, AL =<br />

Slovenia, AM = Mexico),<br />

20 = week 20,<br />

2 = 2002,<br />

E = Friday (A = Monday, etc.),<br />

220 = nominal voltage,<br />

7 = internal Danfoss Code.<br />

Beginning in 2002 Danfoss started to introduce<br />

a new coding consisting of two lines,<br />

e.g., H47117:<br />

043C12A.<br />

First line:<br />

H4711 = 5 last digits in the code no.,<br />

7 = internal Danfoss Code.<br />

Second line:<br />

04 = week 04,<br />

3 = 2003,<br />

C = Wednesday (A = Monday, etc.),<br />

12 = Internal Danfoss Code,<br />

A = Manufacturing place (A-G = Germany, K-N =<br />

Slovenia, R-S = Mexico).<br />

114 USCOC.PK.000.C1.22 © Danfoss Inc. 01-07 (USCO)