Technical leaflet<br />

Bi-flow filter driers with flare and cu-plated solder connectors, type DMB/DCB<br />

Capacities<br />

R134a, R507, R404A, R407C, <strong>R410A</strong>, R22<br />

Drying and liquid capacity (DCB)<br />

Type Liquid capacity [TR] 2) Drying capacity [lbs. refrigerant] 1) Max<br />

Working<br />

R22<br />

R134a<br />

R407C<br />

R404A<br />

R404A<br />

R22 Pressure<br />

R134a<br />

R407C<br />

R507<br />

<strong>R410A</strong><br />

R507<br />

PS<br />

<strong>R410A</strong> 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F [psig]<br />

DCB 082 / 082s<br />

DCB 083 / 083s<br />

DCB 084 / 084s<br />

DCB 162<br />

DCB 163 / 163s<br />

DCB 164 / 164s<br />

DCB 165 / 165s<br />

DCB 303<br />

DCB 304 / 304s<br />

DCB 305 / 305s<br />

DCB 307s<br />

1.1<br />

2.1<br />

2.4<br />

2.2<br />

5.1<br />

8.0<br />

10.6<br />

5.4<br />

8.0<br />

10.9<br />

12.3<br />

0.8<br />

1.5<br />

1.7<br />

1.5<br />

3.7<br />

5.7<br />

8.3<br />

4.3<br />

5.7<br />

8.0<br />

9.1<br />

1.2<br />

2.3<br />

2.6<br />

2.5<br />

5.7<br />

9.1<br />

11.4<br />

6.0<br />

8.9<br />

12.0<br />

13.4<br />

18.3 16.8 17.2 15.7 15.4 13.7 17.2 15.4<br />

34.4 31.3 32.0 29.3 28.9 25.6 32.2 29.1<br />

84.7 76.7 78.9 72.3 70.8 62.8 79.1 71.4<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

507<br />

1) Drying capacity is based on following<br />

moisture content test standards before<br />

and after drying:<br />

R 134a: From 1050 ppm W to 75 ppm W.<br />

If drying to 50 ppm W is required, reduce<br />

stated capacities by 15%.R 404A, R 507:<br />

From 1020 ppm W to 30 ppm W.<br />

R 407C: From 1020 ppm W to 30 ppm W.<br />

R 410A: From 1050 ppm W to 60 ppm W.<br />

R 22: From 1050 ppm W to 60 ppm<br />

W in accordance with ARI 710-86.<br />

2) Capacity given in accordance with ARI<br />

710-86<br />

t e<br />

= 5°F (−15°C)<br />

t c<br />

= 86°F (30°C)<br />

∆p = 1 psig (0.07 bar).<br />

R134a, R507, R404A, R407C, <strong>R410A</strong>, R22<br />

Drying and liquid capacity (DMB)<br />

Type Liquid capacity [TR] 2) Drying capacity [lbs. refrigerant] 1) Max<br />

R134a R404A R22 R134a<br />

R407C<br />

Working<br />

R404A<br />

R22<br />

R507 R407C R507<br />

<strong>R410A</strong><br />

Pressure<br />

<strong>R410A</strong><br />

PS<br />

75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F [psig]<br />

DMB 082 / 082s<br />

DMB 083 / 083s<br />

DMB 084 / 084s<br />

DMB 162<br />

DMB 163 / 163s<br />

DMB 164 / 164s<br />

DMB 165 / 165s<br />

DMB 303<br />

DMB 304 / 304s<br />

DMB 305 / 305s<br />

DMB 307s<br />

1.1<br />

2.1<br />

2.4<br />

2.2<br />

5.1<br />

8.0<br />

10.6<br />

5.4<br />

8.0<br />

10.9<br />

12.3<br />

0.8<br />

1.5<br />

1.7<br />

1.5<br />

3.7<br />

5.7<br />

8.3<br />

4.3<br />

5.7<br />

8.0<br />

9.1<br />

1.2<br />

2.3<br />

2.6<br />

2.5<br />

5.7<br />

9.1<br />

11.4<br />

6.0<br />

8.9<br />

12.0<br />

13.4<br />

20.3 18.7 19.2 17.9 17.6 16.1 19.2 17.6<br />

39.2 36.4 37.0 34.6 34.0 31.1 37.0 34.4<br />

95.9 89.1 90.4 84.7 83.3 76.3 90.8 84.0<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

610<br />

507<br />

© Danfoss Inc. 01-07 (USCO)<br />

USCOC.PK.000.C1.22<br />