Technical leaflet<br />

Hermetic Condensing Units, type CMW/CMEW/CLW/CLEW–Water Cooled<br />

Pressure Controls<br />

Medium Temp CMW = R 22 CMEW = R 134a Low Temp CLW = R 502<br />

CLEW = R 404A/R 507<br />

Code no. Description CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CLW CLW CLW CLW CLW CLW<br />

CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CLEW CLEW CLEW CLEW CLEW CLEW<br />

18 22 28 36 50 64 72 80 100 125 144 160 22 28 44 50 88 100<br />

6902502 Dual Pressure Control for all models X X X X X X X X X X X X X X X X X X<br />

6902507 Dual Pressure Control / Auto reset X X X X X X X X X X X X X X X X X X<br />

Run Capacitators<br />

Medium Temp CMT = R 22 CMTE = R 134a Low Temp CLT = R 502<br />

CLTE = R 404A/R 507<br />

Code no. Description CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CLW CLW CLW CLW CLW CLW<br />

7304533 25 MFD 440 VAC X<br />

7304519 35 MFD 440 VAC<br />

CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CLEW CLEW CLEW CLEW CLEW CLEW<br />

18 22 28 36 50 64 72 80 100 125 144 160 22 28 44 50 88 100<br />

7304522 45 MFD 440 VAC X X X X X X X<br />

7304523 55 MFD 440 VAC X<br />

7304528 50 MFD 440 VAC X X<br />

Pre-wired Start Relay and Capacitor<br />

Assembly<br />

Medium Temp CMT = R 22 CMTE = R 134a Low Temp CLT = R 502<br />

CLTE = R 404A/R 507<br />

Code no. Description CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CLW CLW CLW CLW CLW CLW<br />

7305548<br />

CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CLEW CLEW CLEW CLEW CLEW CLEW<br />

18 22 28 36 50 64 72 80 100 125 144 160 22 28 44 50 88 100<br />

All units except ones using MT(Z)<br />

18-1 X X X X X X X X X X X X X X X X X<br />

7305541 For units using MT(Z) 18-1 X<br />

Contactors<br />

Medium Temp CMT = R 22 CMTE = R 134a Low Temp CLT = R 502<br />

CLTE = R 404A/R 507<br />

Code no. Description CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CMW CLW CLW CLW CLW CLW CLW<br />

CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CMEW CLEW CLEW CLEW CLEW CLEW CLEW<br />

18 22 28 36 50 64 72 80 100 125 144 160 22 28 44 50 88 100<br />

7305502 600v, 3pole, 60A, 208-240 coil 144-3 160-3<br />

7305503 600v, 3pole, 40A, 208-240 coil 64-3 72-3 100-3 144-4 160-4 88-3 100-3<br />

7305504 600v, 3pole, 30A, 208-240 coil 50-3 125-4 50-3 100-4<br />

7305507 600v, 2pole, 50A, 208-240 coil 64-1<br />

7305508 600v, 2pole, 40A, 208-240 coil 50-1 50-1<br />

7305510 600v, 3pole, 25A, 208-240 coil 18-3,4 22-3,4 36-3,4 50-4 64-4 72-4 72-4 100-4 22-3,4 28-3,4 44-3,4 50-4 88-4<br />

7305512 600v, 2pole, 25A, 208-240 coil 28-1<br />

7305513 600v, 2pole, 30A, 204-240 coil 36-1 44-1<br />

7305514 600v, 2pole, 20A, 204-240 coil 18-1 22-1 22-1<br />