Element Description CGI command<br />
SETI0 Simulates the a set on I0 c=85<br />
RESETI0 Simulates a reset on I0 c=86<br />
SETI1 Simulates the a set on I1 c=87<br />
RESETI1 Simulates a reset on I1 c=88<br />
SETCTS Simulates the a set on CTS c=89<br />
RESETCTS Simulates a reset on CTS c=90<br />
SERIAL, TCP or UDP<br />
command<br />
0x63 0x3D 0x38 0x35<br />
0x00 (c=85↲)<br />
0x63 0x3D 0x38 0x36<br />
0x00 (c=86↲)<br />
0x63 0x3D 0x38 0x37<br />
0x00 (c=87↲)<br />
0x63 0x3D 0x38 0x38<br />
0x00 (c=88↲)<br />
0x63 0x3D 0x38 0x39<br />
0x00 (c=89↲)<br />
0x63 0x3D 0x39 0x30<br />
0x00 (c=90↲)<br />
FORCETALK<br />
Starts talking/streaming even if there is an<br />
incoming stream<br />
c=91<br />
0x63 0x3D 0x39 0x31<br />
0x00 (c=91↲)<br />
FORCETALKT<br />
Like FORCETALK but stops sending after<br />
200ms (for keypad)<br />
c=92<br />
0x63 0x3D 0x39 0x32<br />
0x00 (c=92↲)<br />
SETTALKT<br />
DEFAULTS<br />
Like SETTALK but stops sending after 200ms<br />
(for keypad)<br />
Set factory defaults without the network<br />
settings (without own IP, Gateway, Netmask<br />
and SonicIP) and reboots the device.<br />
c=93<br />
c=94<br />
PULSERTS Pulses RTS during the RTS pulse duration c=95<br />
DEVICERESET Hard reboot of device. c=99<br />
0x63 0x3D 0x39 0x33<br />
0x00 (c=93↲)<br />
0x63 0x3D 0x39 0x34<br />
0x00 (c=94↲)<br />
0x63 0x3D 0x39 0x35<br />
0x00 (c=95↲)<br />
0x63 0x3D 0x39 0x39<br />
0x00 (c=99↲)<br />
BOOTLOADER<br />
Starts the bootloader. The application will be<br />
left. It isn't running until the next reboot.<br />
c=100<br />
0x63 0x3D 0x31 0x30<br />
0x30 0x00 (c=100↲)<br />
DISCOVER<br />
If this command is received the device<br />
answers with the file discover.ack.<br />
c=65535<br />
0x63 0x3D 0x36 0x35<br />
0x35 0x33 0x35 0x00<br />
(c=65535↲)<br />
PASSWORD<br />
Concatenate this command to the rest of the<br />
command sequence if the command interface<br />
is password (level 3) protected. The password<br />
has to be added in plain text.<br />
a=…<br />
0x61 0x3D … 0x00<br />
(a=…↲)<br />
8 Software Application Interface