MiNET <strong>Specification</strong><br />

This command shall be used by the system to activate/deactivate the indicated<br />

relay(s).<br />

MT Octet 1<br />

RCTL Octet 2<br />

RLY<br />

Figure 12/MTS<strong>22</strong>-C<br />

Set Relay message format<br />

The RCTL (relay control) octet is defined as follows (decimal):<br />

0 = deactivate<br />

1 = activate<br />

The RLY (relay) octet is defined as follows (decimal):<br />

1-254 = relay number<br />

255 = all relays<br />

Octet 3<br />

4.2.1.10 Pager Module Ringing (D6)<br />

The format of this command shall be as shown in Figure 13/MTS<strong>22</strong>-C.<br />

This command shall be used by the system to control a ringing cycle in a device that is controlling a Paging<br />

Unit. Cadence pattern and repeat pattern is implementation dependant.<br />

MT Octet 1<br />

PMCTL Octet 2<br />

Figure 13/MTS<strong>22</strong>-C<br />

Pager Module Ringing message format<br />

The PMCTL (pager module control) octet is defined as follows (decimal):<br />

00 = deactivate<br />

01 = activate<br />

4.2.2 Responses from terminal to system<br />

4.2.2.1 Report Set ID (C1)<br />

The format of this response shall be as shown in Figure 14/MTS<strong>22</strong>-C.<br />

This response shall be sent by a terminal on power-up, and shall also be sent in response to a Request Set<br />

ID command (see §<br />

4.2.1.1).<br />

MT Octet 1<br />

ID Octet 2<br />

CONFIG<br />

Octet 3<br />

PST (optional) Octet 4<br />

Figure 14/MTS<strong>22</strong>-C<br />

Report Set ID response format<br />

The values (in hexadecimal) and meanings currently defined for the ID octet are shown below:<br />

Note- Bit 7 of the ID octet is traditionally used to differentiate voice (bit=1) and data (bit=0) terminals.<br />

ID octet:<br />

00 = asynchronous dataset (DS1100)<br />

01 = low speed synchronous dataset (DS2100)<br />

02 = high speed synchronous dataset (DS<strong>22</strong>00)<br />

03 = IBM 3278 terminal dataset (DS4113)<br />

04 = IBM 3274 controller dataset (DS41<strong>22</strong>)<br />

05 = Printer port option on DNIC LCD console<br />

<strong>Mitel</strong> Restricted MTS<strong>22</strong> (Version B05) 3:12 PM 30/12/10Page 26 of 173