15.03.2015 Views

“Wires-only” VDSL2 Modem Test Plan - NICC

“Wires-only” VDSL2 Modem Test Plan - NICC

“Wires-only” VDSL2 Modem Test Plan - NICC

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

34<br />

<strong>NICC</strong> ND 1436 V1.1.2 (2013-09)<br />

Equipment Metric Name (/G.997.1)<br />

xTU-R Vendor ID, xTU-R G.994.1 Vendor ID 7.4.2/G.997.1<br />

xTU-R system vendor ID, 7.4.4/G.997.1<br />

xTU-R version number, 7.4.6/G.997.1<br />

xTU-R serial number, 7.4.8/G.997.1<br />

FEC seconds-line far end (downstream), FECS-LFE (7.2.1.2.1/G.997.1)<br />

Errored second-line far end (downstream), ES-LFE (7.2.1.2.2/G.997.1)<br />

Severely errored second-line far end (downstream), SES-LFE (7.2.1.2.3/G.997.1)<br />

Upstream line attenuation, LATNus 7.5.1.10/G.997.1<br />

Downstream line attenuation, LATNds 7.5.1.9/G.997.1<br />

Upstream signal-to-noise (SNR) ratio margin, SNRMus 7.5.1.16/G.997.1<br />

Downstream signal-to-noise ratio margin, SNRMds 7.5.1.13/G.997.1<br />

Upstream data rate<br />

Downstream data rate<br />

Upstream maximum attainable data rate, ATTNDRus 7.5.1.20/G.997.1<br />

Downstream maximum attainable data rate, ATTNDRds 7.5.1.19/G.997.1<br />

Upstream traffic count<br />

Downstream traffic count<br />

Upstream Actual Aggregate Transmit Power, ACTATPus 7.5.1.25/G.997.1<br />

INMINPEQ downstream, 7.2.1.5.1/G.997.1-200711-Amd2<br />

INMIIAT Downstream, 7.2.1.5.3/G.997.1-200711-Amd2<br />

INMME downstream, 7.2.1.5.3/G.997.1-200711-Amd2<br />

Actual INP Upstream, ACTINP 7.5.2.4/G.997.1<br />

Actual INP Downstream, ACTINP 7.5.2.4/G.997.1<br />

Downstream H(f) logarithmic subcarrier group size, HLOGGds 7.5.1.26.5/G.997.1<br />

Downstream H(f) logarithmic representation, HLOGpsds 7.5.1.26.6/G.997.1<br />

Downstream QLN(f) subcarrier group size, QLNGds 7.5.1.27.2/G.997.1<br />

Downstream QLN(f) , QLNpsds 7.5.1.27.3/G.997.1<br />

Downstream SNR(f) subcarrier group size, SNRGds 7.5.1.28.2/G.997.1<br />

Downstream SNR(f), SNRpsds 7.5.1.28.3/G.997.1<br />

Downstream bits allocation, BITSpsds 7.5.1.29.1/G.997.1<br />

Forward error correction – Channel far-end, FEC-CFE 7.2.2.2.2/G.997.1<br />

Table B.10 : Key <strong>Test</strong> and Diagnostic Parameters (taken from G.997.1[10])<br />

<strong>NICC</strong> Standards Limited

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!