<strong>NICC</strong> ND 1436 V1.1.2 (2013-09)<br />

Annex C (normative):<br />

MPF Provider Specific Requirements<br />

C.1 Openreach<br />

C.1.1 Handshake<br />

Compliance shall be determined by the following test .<br />

Carrier Set Designation<br />

Upstream Carrier Sets<br />

Tone<br />

Numbers<br />

Maximum<br />

power<br />

level/carrier<br />

(dBm)<br />

Downstream Carrier Sets<br />

Tone<br />

Numbers<br />

Maximum<br />

power<br />

level/carrier<br />

(dBm)<br />

A43 9 17 25 -1.65 40 56 64 -3.65<br />

A43c 9 17 25 -1.65 257 293 337 -3.65<br />

Table C.1 : Carrier Sets A43 and A43c<br />

Note that the use of additional tone-sets (B43, B43c, V43 etc.) is not permitted as these may cause<br />

the spectral limits defined in Parts B and C of the BT ANFP [6] to be breached.<br />

Power Meter<br />

Baluns<br />

Spectrum<br />

Analyser<br />

PC<br />

DSLAM<br />

Match<br />

Pad<br />

Line Simulator<br />

CPE<br />

PC<br />

PC<br />

Figure C.1 : <strong>Test</strong> Configuration for Measuring Downstream PSD<br />

<strong>Test</strong> Procedure – The <strong>Test</strong> Configuration shown in Figure C.1 shall be used for this test.<br />

1) Set the spectrum analyser for a start frequency of 10kHz and a stop frequency of 5MHz.<br />

2) Configure the DSLAM to implement an E-side electrical length (ESEL) value of 30dB and the<br />

default band profile.<br />