16.04.2015 Views

Gas Management Systems System Components Catalogue – ISO Standard

With over 50 years of experience in the planning and manufacturing of medical gas management systems, Dräger is one of the market and technology leaders in Germany as well as in the international market. Our systems, installed and maintained by Dräger installation specialists and DrägerService technicians, offer premium reliability and safety, above-average durability, and meet the highest quality standards. Medical gases (oxygen, compressed air, nitrous oxide, and carbon dioxide) and vacuum must be safely and reliably available at all times. We deliver tailor-made system solutions, so that your hospital always has the correct gas available in the correct quantities and quality. From planning consultation to assembly and subsequent after-sales service, we provide complete services from one source regardless of whether it is a new development, an enlargement or a renovation. Not all articles are available worldwide.

With over 50 years of experience in the planning and manufacturing of medical
gas management systems, Dräger is one of the market and technology leaders
in Germany as well as in the international market.
Our systems, installed and maintained by Dräger installation specialists and
DrägerService technicians, offer premium reliability and safety, above-average
durability, and meet the highest quality standards.
Medical gases (oxygen, compressed air, nitrous oxide, and carbon dioxide) and
vacuum must be safely and reliably available at all times. We deliver tailor-made
system solutions, so that your hospital always has the correct gas available in the
correct quantities and quality. From planning consultation to assembly and
subsequent after-sales service, we provide complete services from one source
regardless of whether it is a new development, an enlargement or a renovation.
Not all articles are available worldwide.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ALARM SYSTEMS | GAS MANAGEMENT SYSTEMS | 107<br />

ALARM MANAGEMENT SYSTEM<br />

ALARM MANAGEMENT SYSTEM<br />

GAS COMMUNICATION COCKPIT - GCC 1000<br />

The Dräger <strong>Gas</strong> Communication Cockpit GCC 1000 is a high-resolution<br />

8.4“ touch panel and serves as an optional secondary display unit for<br />

graphic visualization of alarms, operating status, measuring values and<br />

gas concentrations from the Alarm <strong>Management</strong> <strong>System</strong> (AMS) and the<br />

<strong>Gas</strong> Detection <strong>System</strong> (GDS).<br />

D-58000-2012<br />

Dräger GCC 1000<br />

The Dräger <strong>Gas</strong> Communication Cockpit is the perfect completition to the<br />

Dräger Alarm <strong>Management</strong> <strong>System</strong>. The Cockpit allows to view and manage<br />

alarms and measured values from the Dräger <strong>Gas</strong> <strong>Management</strong> <strong>System</strong> and<br />

optional the Dräger <strong>Gas</strong> Detection <strong>System</strong>. Forwarding of these alarms and<br />

measurements to external systems, such as a building management system,<br />

intranet and the internet is possible as well as sending SMS and e-mail.<br />

As a system overlapping, secondary display unit the Dräger GCC 1000 is<br />

not liable to the Medical Devices Act (MPG).<br />

<strong>Gas</strong> Communication Cockpit GCC 1000<br />

G42000<br />

The following components for the GCC 1000<br />

are available within the configuration:<br />

GCC 1000 Touch Panel<br />

LON-Modbus Gateway<br />

Surf.-mounted housing GCC 1000<br />

Flush-mounted housing for GCC 1000<br />

G42630<br />

G42633<br />

G42632<br />

G42631<br />

The following software options for the GCC 1000<br />

are available within the configuration for the initial equipment or retrofitting:<br />

Option GDS<br />

G42634<br />

Option Datalogger<br />

G42636<br />

Option BacNet<br />

G42639<br />

Option GSM<br />

GSM Module<br />

G42635<br />

G42724