16.04.2015 Views

Gas Management Systems System Components Catalogue – ISO Standard

With over 50 years of experience in the planning and manufacturing of medical gas management systems, Dräger is one of the market and technology leaders in Germany as well as in the international market. Our systems, installed and maintained by Dräger installation specialists and DrägerService technicians, offer premium reliability and safety, above-average durability, and meet the highest quality standards. Medical gases (oxygen, compressed air, nitrous oxide, and carbon dioxide) and vacuum must be safely and reliably available at all times. We deliver tailor-made system solutions, so that your hospital always has the correct gas available in the correct quantities and quality. From planning consultation to assembly and subsequent after-sales service, we provide complete services from one source regardless of whether it is a new development, an enlargement or a renovation. Not all articles are available worldwide.

With over 50 years of experience in the planning and manufacturing of medical
gas management systems, Dräger is one of the market and technology leaders
in Germany as well as in the international market.
Our systems, installed and maintained by Dräger installation specialists and
DrägerService technicians, offer premium reliability and safety, above-average
durability, and meet the highest quality standards.
Medical gases (oxygen, compressed air, nitrous oxide, and carbon dioxide) and
vacuum must be safely and reliably available at all times. We deliver tailor-made
system solutions, so that your hospital always has the correct gas available in the
correct quantities and quality. From planning consultation to assembly and
subsequent after-sales service, we provide complete services from one source
regardless of whether it is a new development, an enlargement or a renovation.
Not all articles are available worldwide.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

24 | GAS MANAGEMENT SYSTEMS | COMPRESSED AIR SYSTEMS<br />

COMPRESSED AIR SYSTEMS<br />

MT-8748-2006<br />

MT-5145-2004<br />

Whether for normal care, the ICU, the ER or the OR, medical gas supply is of<br />

major importance for almost every area of the hospital. Central compressed air<br />

systems ensure the continuous supply of medical compressed air of proper<br />

quality and pressure.<br />

D-105958-2013<br />

Dräger has been building central compressed<br />

air supply systems for hospitals, clinics, and<br />

medical practices for over fifty years. Today's<br />

systems meet all the current standards, in particular<br />

DIN EN <strong>ISO</strong> 7396-1, with air quality in<br />

accordance with the European Pharmacopoeia.<br />

After manufacture, every system is<br />

carefully inspected and labeled with a CE certificate<br />

on release. EcoPharm Tower systems,<br />

extremely effective compressed air purification<br />

systems with five filtering stages and an<br />

adsorption dryer, ensure the purity of the<br />

compressed air. These systems are equipped<br />

with three compressors and two compressed<br />

air receivers, filter systems, and pressure<br />

reducer stations. They are constructed in<br />

such a way to ensure the utmost reliability as<br />

well as to maintain and repair without having<br />

to interrupt normal operations.<br />

Medical Air Plants acc. to <strong>ISO</strong> 7396-1<br />

Main components of a Dräger Medical<br />

Air Plant are 3 or 4 compressors, an<br />

energy or control panel, 2 air receivers,<br />

2 EcoPharm-Towers 5-stage<br />

conditioning systems with filters and<br />

adsorption dryers and a pressure<br />

reducer station. The installation fully<br />

complies with the standard DIN EN <strong>ISO</strong><br />

7396-1 and the produced air is air for<br />

medical use according to the European<br />

Pharmacopoeia.<br />

The compressors build the three air<br />

sources of the plant. Taking various<br />

aspects into consideration e.g.<br />

economics, reliability, service, oil<br />

lubricated compressors are selected.<br />

The air receiver’s capacity size is<br />

related to the compressors output to<br />

comply with the hourly stop and start ratio<br />

laid down by the manufacturer and<br />

produce steady flow. The EcoPharm-<br />

Tower conditioning systems reduce the<br />

air humidity to an atmospheric dew point<br />

of -46°C to prevent condensate in the<br />

piping system and allow the filter system<br />

to achieve the air quality according to the<br />

European Pharmacopoeia.<br />

The pressure reducer stations related to<br />

flow provide constant line distribution<br />

pressure for breathing systems and<br />

surgical tools.