16.04.2015 Views

Gas Management Systems System Components Catalogue – ISO Standard

With over 50 years of experience in the planning and manufacturing of medical gas management systems, Dräger is one of the market and technology leaders in Germany as well as in the international market. Our systems, installed and maintained by Dräger installation specialists and DrägerService technicians, offer premium reliability and safety, above-average durability, and meet the highest quality standards. Medical gases (oxygen, compressed air, nitrous oxide, and carbon dioxide) and vacuum must be safely and reliably available at all times. We deliver tailor-made system solutions, so that your hospital always has the correct gas available in the correct quantities and quality. From planning consultation to assembly and subsequent after-sales service, we provide complete services from one source regardless of whether it is a new development, an enlargement or a renovation. Not all articles are available worldwide.

With over 50 years of experience in the planning and manufacturing of medical
gas management systems, Dräger is one of the market and technology leaders
in Germany as well as in the international market.
Our systems, installed and maintained by Dräger installation specialists and
DrägerService technicians, offer premium reliability and safety, above-average
durability, and meet the highest quality standards.
Medical gases (oxygen, compressed air, nitrous oxide, and carbon dioxide) and
vacuum must be safely and reliably available at all times. We deliver tailor-made
system solutions, so that your hospital always has the correct gas available in the
correct quantities and quality. From planning consultation to assembly and
subsequent after-sales service, we provide complete services from one source
regardless of whether it is a new development, an enlargement or a renovation.
Not all articles are available worldwide.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

COMPRESSED AIR SYSTEMS | GAS MANAGEMENT SYSTEMS | 43<br />

ECOPHARM TOWER<br />

TECHNICAL DATA ECOPHARM TOWER MA DMET 002S-008S<br />

Description Order no. Flow rate AIR-connections Weight E-connection E-power consumption<br />

m³/h (l/min) kg V/Hz Watt<br />

MA DMET 002S G91770 5.3 1) /8 2) (88/133) G½-G½ 8.1 230 <strong>–</strong> 50/60 75<br />

MA DMET 003S G91771 10.5 1) /16 2) (175/267) G½-G½ 12.6 230 <strong>–</strong> 50/60 75<br />

MA DMET 004S G91772 15.8 1) /26 2) (263/433) G½-G½ 17.6 230 <strong>–</strong> 50/60 75<br />

MA DMET 008S G91773 26.3 1) /39 2) (438/650) G½-G½ 22.7 230 <strong>–</strong> 50/60 75<br />

1)<br />

Related to AIR at STP, measured at 7 bar and 35° C inlet temperature<br />

2)<br />

Related to AIR at STP, measured at 12 bar and 36 <strong>–</strong> 40° C inlet temperature<br />

TECHNICAL DATA ECOPHARM TOWER MA DME 012S-080S<br />

Description Order no. Flow rate AIR-connections Weight E-connection E-power consumption<br />

m³/h (l/min) kg V/Hz Watt<br />

MA DME 012S G30622 40.0 1) /54 2) (666/900) G½-G½ 38 230 <strong>–</strong> 50/60 75<br />

MA DME 015S G30623 53.0 1) /72 2) (883/1200) G½-G¾ 43 230 <strong>–</strong> 50/60 75<br />

MA DME 020S G30624 70.0 1) /93 2) (1166/1549) G½-G¾ 48 230 <strong>–</strong> 50/60 75<br />

MA DME 025S G30625 90.0 1) /118 2) (1500/1966) G½-G¾ 53 230 <strong>–</strong> 50/60 75<br />

MA DME 030S G30626 110.0 1) /144 2) (1833/2400) G½-G¾ 58 230 <strong>–</strong> 50/60 75<br />

MA DME 040S G30627 144.0 1) /195 2) (2400/3249) G½-G¾ 74 230 <strong>–</strong> 50/60 75<br />

MA DME 050S G30628 179.0 1) /236 2) (2983/3932) G1-G1 217 230 <strong>–</strong> 50/60 75<br />

MA DME 060S G30629 220.0 1) /284 2) (3666/4731) G1-G1 230 230 <strong>–</strong> 50/60 75<br />

MA DME 080S G30630 288.0 1) /356 2) (4800/5931) G1-G1 285 230 <strong>–</strong> 50/60 75<br />

1)<br />

Related to AIR at STP, measured at 7 bar and 35° C inlet temperature<br />

2)<br />

Related to AIR at STP, measured at 12 bar and 36 <strong>–</strong> 40° C inlet temperature