16.04.2015 Views

Gas Management Systems System Components Catalogue – ISO Standard

With over 50 years of experience in the planning and manufacturing of medical gas management systems, Dräger is one of the market and technology leaders in Germany as well as in the international market. Our systems, installed and maintained by Dräger installation specialists and DrägerService technicians, offer premium reliability and safety, above-average durability, and meet the highest quality standards. Medical gases (oxygen, compressed air, nitrous oxide, and carbon dioxide) and vacuum must be safely and reliably available at all times. We deliver tailor-made system solutions, so that your hospital always has the correct gas available in the correct quantities and quality. From planning consultation to assembly and subsequent after-sales service, we provide complete services from one source regardless of whether it is a new development, an enlargement or a renovation. Not all articles are available worldwide.

With over 50 years of experience in the planning and manufacturing of medical
gas management systems, Dräger is one of the market and technology leaders
in Germany as well as in the international market.
Our systems, installed and maintained by Dräger installation specialists and
DrägerService technicians, offer premium reliability and safety, above-average
durability, and meet the highest quality standards.
Medical gases (oxygen, compressed air, nitrous oxide, and carbon dioxide) and
vacuum must be safely and reliably available at all times. We deliver tailor-made
system solutions, so that your hospital always has the correct gas available in the
correct quantities and quality. From planning consultation to assembly and
subsequent after-sales service, we provide complete services from one source
regardless of whether it is a new development, an enlargement or a renovation.
Not all articles are available worldwide.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

COMPRESSED AIR SYSTEMS | GAS MANAGEMENT SYSTEMS | 31<br />

SCREW COMPRESSORS DWLC/DWLS SERIES<br />

TECHNICAL DATA SCREW COMPRESSOR DWLC/DWLS TYPES 50 HZ<br />

Color<br />

Operating voltage<br />

Control voltage<br />

RAL 5012 (blue)<br />

400 V/50 Hz AC<br />

230 V/50 Hz AC<br />

Description Order no. Free air delivery 1) Motor/fan AIR outlet Fan thrust Cooling air Sound level 2) Weight<br />

demand<br />

m³/h (l/min) kW Pa Nm³/h dB(A) kg<br />

DWLC 7 (Focus) 50 Hz Slave G31455 39.12 (652) 5.5 G½ 50 1500 64 243.5<br />

DWLC 7 (Focus) 50 Hz Master G31355 39.12 (652) 5.5 G½ 50 1500 64 243.5<br />

DWLC 9 (Focus) 50 Hz Slave G31456 54 (900) 7.5 G½ 50 2000 68 219<br />

DWLC 9 (Focus) 50 Hz Master G31356 54 (900) 7.5 G½ 50 2000 68 219<br />

Dimensions (L×W×H)<br />

480 × 920 × 960 mm<br />

DWLC 15 (Focus) 50 Hz Slave G31457 79.8 (1330) 11.0 G1 50 1700 67 410<br />

DWLC 15 (Focus) 50 Hz Master G31357 79.8 (1330) 11.0 G1 50 1700 67 410<br />

DWLC 20 (Focus) 50 Hz Slave G31458 113.4 (1890) 15.0 G1 50 2500 65 438<br />

DWLC 20 (Focus) 50 Hz Master G31358 113.4 (1890) 15.0 G1 50 2500 65 438<br />

DWLC 25 (Focus) 50 Hz Slave G31459 139.2 (2320) 18.5 G1 50 3100 68 499<br />

DWLC 25 (Focus) 50 Hz Master G31359 139.2 (2320) 18.5 G1 50 3100 68 499<br />

DWLC 30 (Focus) 50 Hz Slave G31460 162.6 (2710) 22.0 G1 50 3450 69 461<br />

DWLC 30 (Focus) 50 Hz Master G31360 162.6 (2710) 22.0 G1 50 3450 69 461<br />

Dimensions (L×W×H)<br />

772 × 1056 × 1735 mm<br />

DWLS 40 (Focus) 50 Hz Slave G31467 229.2 (3820) 30.0 G1¼ 60 5500 76 784<br />

DWLS 40 (Focus) 50 Hz Master G31367 229.2 (3820) 30.0 G1¼ 60 5500 76 784<br />

DWLS 50 (Focus) 50 Hz Slave G31468 297 (4950) 37.0 G1¼ 60 6500 78 804<br />

DWLS 50 (Focus) 50 Hz Master G31368 297 (4950) 37.0 G1¼ 60 6500 78 804<br />

Dimensions (L×W×H)<br />

1615 × 990 × 1450 mm<br />

1)<br />

Acc. to VDMA 4362 related to STP<br />

2)<br />

Acc. to DIN 45635-part 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!