tandem vector owner's manual
tandem vector owner's manual
tandem vector owner's manual
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SIGMA TANDEM SYSTEM OWNER’S MANUAL<br />
PROBLEM: Left arm is held.<br />
REACTION: If he has your left arm, hit him on the side of his head as hard as you can; he’ll probably let go. If you<br />
cannot free your left arm, throw the drogue and release it at the proper altitude.<br />
PROBLEM: Both arms are held.<br />
REACTION: If a student gets both arms, a quick, rearward extraction movement of both hands can generally free you<br />
at once. If unsuccessful, you still have your voice, your head, your teeth and your knees to work with.<br />
ANALYSIS: A student that panics is apt to do almost anything. This type of incident has been reported enough times<br />
for us to know that it can and will happen again. The best course of action is a preventative one. Keep your arms away<br />
from the student in the first place.<br />
NEVER PUT A WRIST MOUNTED ALTIMETER IN FRONT OF A STUDENTS FACE. This is an engraved invitation to grab<br />
your arm! (See fatality report #6.)<br />
Always tell the student during the pre-jump briefing not to grab your arms at any time during the jump. Make it clear<br />
what the consequences might be. Tell the student that you will both die an ugly death by “sudden impact trauma” if<br />
he does interfere with your ability to pull the operating handles.<br />
DROGUE DEPLOYMENT AND RELEASE PROBLEMS<br />
A. Pulling the wrong handle<br />
B. Unable to extract drogue from pouch<br />
C. Un-inflated drogue<br />
D. Entanglement with drogue<br />
E. Entanglement with the drogue bridle<br />
F. Non-collapsed drogue<br />
G. Drogue does not release when first handle pulled.<br />
A. Pulling the wrong handle:<br />
PROBLEM: You have pulled the drogue release handle before deploying the drogue.<br />
REACTION: Deploy the drogue immediately.<br />
ANALYSIS: If you don’t deploy the drogue promptly, you will of course continue to accelerate towards 170 mph. If<br />
you pull the drogue release and the drogue safety pin is in place nothing will happen.<br />
B. Unable to extract drogue from pouch:<br />
PROBLEM: You are unable to locate the drogue deployment handle or are unable to extract the drogue completely<br />
from its pouch.<br />
REACTION: Pull the reserve ripcord.<br />
11301 - 00.00.0000 Section 4: Malfunctions & Emergencies • Chapter 1 - Reserve Procedures<br />
Page 3:X