SIGMA TANDEM SYSTEM OWNER’S MANUAL<br />

G. Drogue in tow:<br />

PROBLEM: Drogue release handle is pulled, but the main does not deploy, even after a few extra seconds (the time it<br />

would take for an uninflated drogue to deploy the main).<br />

REACTION: For the complete release of the drogue to occur, the drogue closing pin must be extracted from the main<br />

closing loop.<br />

ANALYSIS: If this fails to occur, you will have an INFLATED DROGUE IN TOW. You will notice no trap door effect after<br />

you pull the drogue release handle.<br />

In this case, if the drogue is still in tow at 3,000 ft. AGL, pull the reserve ripcord. It is not necessary to first pull the main<br />

cutaway handle.<br />

A drogue in tow malfunction can almost always be avoided by following the packing instructions correctly.<br />

Once the reserve is open and you’re heading towards the landing area, reach back and reel in the trailing drogue if<br />

altitude permits. If the main canopy should begin to deploy, release the main risers by pulling the breakaway handle.<br />

H) Drogue does not release when first handle is pulled:<br />

PROBLEM: Primary drogue release handle is pulled, but drogue does not release. This malfunction is usually due to<br />

improper alignment of the closing pin.<br />

REACTION: Pull the secondary drogue release handle while still attempting to pull the primary drogue release. (two<br />

hands are stronger than one). If the main still does not deploy, pull the reserve ripcord.<br />

ANALYSIS: This malfunction is usually due to improper alignment of the main pin. This problem can be avoided by<br />

checking the pin configuration against the diagram on the main pin cover.<br />

I) Hard or impossible pull on one or both drogue release handles:<br />

PROBLEM: The drogue had been deployed but the drogue release handles cannot be pulled.<br />

REACTION: Pull the reserve ripcord or pull the ball handle on the RSL to activate the reserve.<br />

11301 - 00.00.0000 Section 4: Malfunctions & Emergencies • Chapter 1 - Reserve Procedures<br />