6.7.2 n-Butanol vapour<br />

The standard reference substance for calibrating panellists is n-butanol in nitrogen.<br />

The recommended concentration <strong>of</strong> n-butanol has not been defined in AS/NZS<br />

4323.3:2001, however, TOU uses a nominal concentration <strong>of</strong> 50 ppm n-butanol in<br />

nitrogen.<br />

A certified cylinder <strong>of</strong> n-butanol in nitrogen was not available for this study so an<br />

alternate method was used which involved injecting n-butanol liquid into a bag <strong>of</strong><br />

clean dry air. The air was obtained from the oil-free compressor which supplied<br />

clean air to the olfactometer and included a carbon filter for removal <strong>of</strong> organic<br />

contaminants.<br />

The concentration <strong>of</strong> 50 ppm n-butanol was achieved by injecting a volume <strong>of</strong><br />

3.73 μL n-butanol into 20L <strong>of</strong> dry air. The bags were left for at least 30 minutes to<br />

equilibrate before initial use.<br />

32 Environmental Publication <strong>2012</strong>/06–A review <strong>of</strong> odour properties <strong>of</strong> H 2 S <strong>Odour</strong> <strong>Threshold</strong> <strong>Investigation</strong> <strong>2012</strong>