Remote Line Controller (RLC) - Grostech.com
Remote Line Controller (RLC) - Grostech.com
Remote Line Controller (RLC) - Grostech.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Remote</strong> <strong>Line</strong> <strong>Controller</strong> (<strong>RLC</strong>)<br />
Product Manual<br />
<strong>RLC</strong> Features<br />
Answers calls from the JANUS system<br />
The <strong>RLC</strong> monitors the modem, if a call is received, the <strong>RLC</strong> will check that it is connected to the<br />
correct JANUS for Windows system. When this is established, it connects the controllers to the<br />
line for automatic transfer of information.<br />
Makes automatic calls to the JANUS system<br />
The <strong>RLC</strong> polls the first eight controller addresses on the <strong>com</strong>ms line, for information on what is<br />
happening on the remote site. If one of the events listed below occurs, the <strong>RLC</strong> connects itself<br />
to the JANUS for Windows system. After providing security and line information, the controllers<br />
are connected for automatic transfer of information.<br />
Compulsory dial-up from the remote site occurs if:<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
A controller goes off-line from the <strong>RLC</strong><br />
A controller requests a config reset<br />
A controller event buffer is nearly full<br />
A controller mains power supply fails<br />
A controller has a tamper or lock power fail<br />
A duress pin occurs<br />
An input tamper occurs<br />
An <strong>RLC</strong> tamper occurs<br />
The <strong>RLC</strong> is powered-up<br />
Low battery voltage is detected for the <strong>RLC</strong><br />
Optional dial-up from the remote site occurs if:<br />
A programmed output group triggers a connection. This can be initiated by an action (the action<br />
would normally take place on activation of an input).<br />
Other features<br />
The <strong>RLC</strong> will attempt to connect to the JANUS for Windows system every minute until it<br />
achieves connection.<br />
Anti-passback and action information is controlled by the <strong>RLC</strong> during periods whilst it is<br />
disconnected from the Main JANUS for Windows site.<br />
The standard controller metal enclosure, PSU and battery backup can be used if wall<br />
mounting. Alternatively, the MDUI, modem-type euro enclosure can be used for desk or<br />
shelf mounting.<br />
The <strong>RLC</strong> can be upgraded by download from the JANUS system in the same way that<br />
an IDC issue 9 board can.<br />
Page 2 of 11 PM004R02 – November 2001<br />
Grosvenor Technology Ltd © 2001