3. General Specifications (Environment Conditions)<br />

3.2 Environment Specifications in Electric Cabinet<br />

3.2 Environment Specifications in Electric Cabinet<br />

Item<br />

General<br />

specifications<br />

Required<br />

Power<br />

specification<br />

Unit name<br />

Remote I/O unit<br />

Type FCUA-DX10 FCUA-DX11 FCUA-DX12 FCUA-DX14<br />

During<br />

Ambient operation<br />

temperature During<br />

storage<br />

0 to 55°C<br />

–20 to 60°C<br />

Ambient Long term 10 to 75% RH (with no dew condensation)<br />

humidity Short term 10 to 95% RH (with no dew condensation) (Note 1)<br />

Vibration resistance<br />

Shock resistance<br />

Working atmosphere<br />

Input power voltage<br />

4.9m/s 2 or less (during operation)<br />

29.4m/s 2 or less (during operation)<br />

No corrosive gases, dust<br />

24VDC±5% Ripple noise 200mV (P-P)<br />

Power capacity 24V 0.7A (Note 2) 24V 1.5A (Note 2) 24V 0.7A (Note 2)<br />

Instantaneous stop<br />

tolerance time<br />

Heating value (Max.) 25W (Note 3) 30W (Note 3) 30W (Note 3)<br />

Others<br />

Mass 0.5kg 0.6kg 0.6kg 0.6kg<br />

(Note 1) The period is within one month.<br />

(Note 2) Amount consumed by control circuit<br />

(Note 3) Differs according to the number of machine input operation points and the load and number of<br />

points connected to the machine output. The maximum value applies when all points are ON.<br />

—<br />