17.05.2015 Views

70 Series Connection Manual - Automation Service Srl

70 Series Connection Manual - Automation Service Srl

70 Series Connection Manual - Automation Service Srl

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

6. <strong>Connection</strong>s of Control Unit<br />

6.2 Connecting with Power Supply<br />

6.2.2 When Using PD25/PD27 Power Supply Unit<br />

(1) <strong>Connection</strong> of PD25/PD27 power supply<br />

PD25/PD27 power supply unit<br />

DCIN<br />

Y<br />

F110 cable<br />

ACIN<br />

MC<br />

NFB<br />

R<br />

S<br />

CF01<br />

T<br />

ACFAIL<br />

(Note)<br />

ON/OFF SW<br />

FG<br />

DCIN<br />

ON/OFF<br />

F1<strong>70</strong> cable<br />

FAN ALARM<br />

POWER<br />

DCOUT<br />

ON<br />

OFF<br />

Control unit<br />

ON/OFF switch<br />

(Note) <strong>70</strong> <strong>Series</strong> does not employ ACFAIL function. (CF01 is not connected.)<br />

<br />

Cable drawing: "Appendix 2 (F110 cable, F1<strong>70</strong> cable)"<br />

Connector pin assignment: "Appendix 3 (DCIN connector)"<br />

ACIN<br />

ON/OFF SW<br />

ON/OFF<br />

FAN ALARM<br />

POWER<br />

ACIN: AC input<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

4<br />

5<br />

ACIN N<br />

ACIN H<br />

FG<br />

ON/OFF SW:<br />

:<br />

NC<br />

P-OFF<br />

0V<br />

0V<br />

P-ON<br />

<br />

Connector : 2-178128-3<br />

Contact : 1-175218-5<br />

Recommended : Tyco Electronics AMP<br />

manufacturer<br />

Switch ON (upward) --- 24VDC output<br />

Switch OFF (downward) --- 24VDC output OFF<br />

ON/OFF: Connect to ON/OFF switch<br />

<br />

Connector : 1-178288-5<br />

Contact : 1-175218-5<br />

Recommended : Tyco Electronics AMP<br />

manufacturer<br />

DCOUT<br />

POWER: Green light at +24V output<br />

DCOUT :<br />

1<br />

2<br />

3<br />

Left connector --- 24VDC output<br />

: Right connector --- Power shutoff detection signal<br />

(ACFAIL) output<br />

A (X) B (Y)<br />

<br />

ACFAIL +24V<br />

Connector : 3-178128-6<br />

0V 0V Contact : 1-175218-5<br />

FG FG<br />

Recommended<br />

manufacturer<br />

: Tyco Electronics AMP<br />

<br />

Connector pin assignment: "Appendix 3 (ACIN connector, ON/OFF connector, DCOUT connector)"<br />

33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!