2. Items related to prevention of fire<br />

CAUTION<br />

Install the controller, drive unit, motor and regenerative resistor on non-combustible material.<br />

Installation directly on or near combustible materials could result in fires.<br />

If any malfunction in the unit is observed, shut off the power at the unit’s power supply side.<br />

Continuous flow of large current could result in fires.<br />

Install an appropriate no fuse breaker (NFB) and contactor (MC) on the power input section of the<br />

drive unit and configure the sequence that shuts the power off upon drive unit’s emergency stop or<br />

alarm.<br />

When a breaker is shared for multiple power supply units, the breaker may not function upon<br />

short-circuit failure in a small capacity unit. Do not share a breaker for multiple units as this is<br />

dangerous.<br />

Incorrect wiring and connections could cause the devices to damage or burn.<br />

3. Items related to prevention of bodily injury or property damage<br />

DANGER<br />

When transporting or installing a built-in IPM spindle or linear servomotor, be careful so that your<br />

hand or property will not be trapped in the motors or other metal objects. Also keep the devices with<br />

low magnetic tolerance away from the product.<br />

CAUTION<br />

Do not apply voltages to the connectors or terminals other than voltages indicated in the connection<br />

manual for the controller or specifications manual for the drive unit. Failure to observe this could<br />

cause the devices to rupture or damage, etc.<br />

Incorrect connections could cause the devices to rupture or damage, etc. Always connect the cables<br />

to the indicated connectors or terminals.<br />

Incorrect polarity (+ -) could cause the devices to rupture or damage, etc.<br />

Persons wearing medical devices, such as pacemakers, must stay away from this unit. The<br />

electromagnetic waves could adversely affect the medical devices.<br />

Fins on the rear of the unit, regenerative resistor and motor, etc., will be hot during operation and for<br />

a while after the power has been turned OFF. Do not touch or place the parts and cables, etc. close<br />

to these sections. Failure to observe this could result in burns.<br />

Do not enter the machine’s movable range during automatic operation. Keep your hands, feet or<br />

face away from the spindle during rotation.