CHAPTER 3 -<br />
VARIOUS FUNCTION SETTING & DESCRIPTION<br />
3.1 Function Setting<br />
3.1.1 Basic function parameter setting<br />
It is the basic function setting. All settings are factory defaults unless users make change. It is recommended to use<br />
factory setting value unless the parameter change is necessary.<br />
1) Common parameter setting<br />
The following table shows common parameter setting that should be checked before use but making change does not<br />
affect inverter control type.<br />
Parameter Name Code Description<br />
Motor Selection FU2-30<br />
Selects motor and voltage rating suitable to the desired<br />
inverter.<br />
Motor parameters FU2-31 ~ 36<br />
Basic parameter value setting when selecting the motor<br />
rating.<br />
Note: If there is any discrepancy between parameter<br />
preset value and the actual motor parameter value,<br />
change the parameter value according to the actual<br />
motor.<br />
Drive Mode DRV-3 Operation via Keypad, Fx/Rx-1, Fx/Rx-2 setting<br />
Frequency/Torque setting parameter<br />
Frequency or<br />
DRV-4 It automatically changes to torque mode when FU2 39-<br />
Torque Mode<br />
[Control mode] is set to Sensorless_T, Vector_TRQ.<br />
Accel/Decel time<br />
setting<br />
DRV-1, DRV-2<br />
Accel/Decel time setting<br />
2) V/f control<br />
FU2-39 [Control mode] is set to 0 (V/F) as factory setting. Operation via V/F control can be performed after common<br />
parameter settings are done and the followings are set.<br />
Parameter Name Code Description<br />
Starting freq. FU1-22 Set frequency to start the motor.<br />
Torque boost FU1-26 Manual or Auto torque boost settable in this parameter<br />
Torque boost value<br />
FU1-27, FU1-28<br />
If FU1-26 [torque boost] is set to manual, user sets the<br />
desired value and the direction in code FU1-27 and 28.<br />