¡Hot keep M mode [During HI POWER operation (for 15 min.)]<br />

Indoor blower<br />

1st speed<br />

2nd speed<br />

3rd speed<br />

4th speed<br />

5th speed<br />

Indoor heat exchanger temp. (˚C)<br />

6th speed<br />

7th speed<br />

8th speed<br />

OFF<br />

a b 29 31 32 34 38 42 50<br />

Note (1) Refer to the table shown above right for the values a and b.<br />

¡ Values of a, b<br />

a b<br />

At 0 Hz command 22 25<br />

Other than 0 Hz<br />

command<br />

17 19<br />

◆SRRM40 model<br />

¡Normal mode<br />

Indoor blower<br />

Hi<br />

Me<br />

Lo<br />

ULo<br />

OFF<br />

a b 38 41 44<br />

Indoor heat exchanger temp. (˚C)<br />

Note (1) Refer to the table shown above right for the values a and b.<br />

¡ Values of a, b<br />

a b<br />

At 0 Hz command 30 33<br />

Other than 0 Hz<br />

command<br />

17 30<br />

(f)<br />

Defrosting<br />

(i) When the following conditions are met, the defrosting operation will start.<br />

1) During normal operation<br />

a) When 30 minutes has passed since the start of heating or 30 minutes after the last defrosting (Cumulative actual<br />

operating time of compressor other than the outdoor unit frequency 0 Hz).<br />

b) When the outdoor heat exchanger thermistor temperature is –2 °C or less for 3 continuous minutes after 27 minutes<br />

have passed.<br />

c) Outdoor thermistor temperature (Th6) – Outdoor gas piping thermistor temperature 0.44 × Outdoor thermistor<br />

temperature + A °C or more. Avalue : Th6 –2°C · 4, Th6 < –2°C · 6<br />

d) When the compressor is operating.<br />

u In addition, defrosting operation will start when the count of the decision frequency has become 0 Hz reaches 10<br />

times or more and when all the conditions presented above in a), b) and d) are met.<br />

2) During defrosting acceleration<br />

a) When 30 minutes has passed since the last defrosting (Cumulative actual operating time of compressor other than<br />

the outdoor unit frequency 0 Hz).<br />

b) When the compressor is operating.<br />

u In addition, defrosting operation will start when the count of the decision frequency has become 0 Hz reaches 10<br />

times or more and when all the conditions presented above in a) and b) are met.<br />

Note (1) Defrosting acceleration is when the finishing of the previous defrosting is according to the defrosting conditions of the 10 minutes that have<br />

passed.<br />

≤<br />

≤<br />

142