(m) Outdoor unit abnormal stop and compressor motor protection<br />

If the air conditioner is operating at an inverter frequency 28 Hz or more and an input current of 1 A or less is detected for 30<br />

continuous seconds or more, a abnormal stop is performed. At the same time, LED 5 on the printed circuit board for the<br />

outdoor unit will flash 2 times at a 0.5 second interval every 8 seconds.<br />

The unit is re-started after 3-minute's delay, however, if the re-start has been performed 3 times within 1 hour, the fifth start<br />

cannot be performed. (The timer lamp on the indoor unit will flash 2 times.)<br />

(n) Serial transmission abnormality protection<br />

An abnormal stop is made if the outdoor unit does not receive serial signal commands, other than “Stop: 0 Hz,” from all the<br />

indoor controllers continuously for 1 minute and 55 seconds when the compressor is operating at an outdoor frequency of<br />

other than 0 Hz. At the same time, LED 5 on the printed circuit board for the outdoor unit will flash 6 times at a 0.5 second<br />

interval every 8 seconds. (The timer lamp on the indoor unit will flash 6 times.)<br />

The unit can be restarted if serial signal is restored and/or the 3-minute delay has finished.<br />

(o) Stop mode : When the decision frequency is 0 Hz; during switching mode, during protection function<br />

operation.<br />

Functional<br />

components<br />

Operation<br />

If stopped by indoor unit control. If permanent stop. If stopped by outdoor protection function. If restarted by operation switching.<br />

Heating Cooling Heating<br />

Cooling<br />

Outdoor unit<br />

frequency<br />

Decision frequency<br />

0 Hz<br />

2 minutes 55 seconds<br />

2 minutes 55 seconds<br />

Outdoor unit fan<br />

According to Hz<br />

OFF<br />

4-Way valve<br />

(20S)<br />

ON<br />

OFF<br />

2 minutes<br />

55<br />

seconds<br />

2 minutes 2 minutes<br />

2 minutes<br />

55 seconds<br />

EEVA<br />

EEV<br />

control<br />

Fully<br />

closed<br />

200 Pulse<br />

2 minutes<br />

25seconds<br />

200 Pulse<br />

2 minutes<br />

25seconds<br />

200 Pulse<br />

2 minutes<br />

25seconds<br />

200 Pulse<br />

2 minutes<br />

25seconds<br />

EEVB<br />

EEVC<br />

Operated<br />

successively<br />

EEV<br />

control<br />

Fully<br />

closed<br />

200 Pulse 200 Pulse 200 Pulse 200 Pulse<br />

Stopped<br />

(0 Hz command)<br />

All stopped<br />

Stopped<br />

(0 Hz command)<br />

All stopped<br />

Stopped<br />

(0 Hz command)<br />

Restart<br />

Stopped<br />

(0 Hz command)<br />

Restart<br />

146