Securing the Unit<br />

¡ Locations to secure the bolts.<br />

¡ Use M10-M12 for the retaining bolts.<br />

¡ Secure it firmiy so the unit will not fall during earthquakes and from sudden gusts of wind.<br />

Drainage<br />

¡ There are 3 holes in the bottom panel of<br />

the outdoor unit to drain condensation.<br />

Removing the Outer Panel<br />

2 Top panel<br />

1 Service panel<br />

1 Service panel<br />

¡Remove the screws, and pull the panel toward the direction.<br />

2 Top panel<br />

¡Remove the panel when cheking the abnormal indicator LED<br />

during the protective function.<br />

<strong>4.</strong>5.4 Setting for current limit SW (for SCM68YA, cooling only type)<br />

This unit has a current limit default velue of Max.Amp (17.5A) to change<br />

the default value, remove the front panel and set the switch fot the printed<br />

circit board etc., according to the following instructions.<br />

1 Changing the current limit to 11A.<br />

Turn on the SW6 shown in the figure.<br />

2 Changing the current limit to 8.5A.<br />

Turn on the SW5 and SW6 shown in the figure.<br />

CURRENT LIMIT SW<br />

SW5<br />

SW6<br />

11A<br />

SW5<br />

SW6<br />

8.5A<br />

SW5<br />

SW6<br />

ON<br />

OFF<br />

MAX.AMP.<br />

154