Cautions when piping from the left and the rear center of the unit<br />

[Top View]<br />

Left Side Piping<br />

Left rear piping<br />

Right Side Piping<br />

Right rear piping<br />

The piping can be removed from<br />

the rear, left, left rear, right and<br />

from under the unit.<br />

Left side piping<br />

Right side piping<br />

Right<br />

Rear<br />

Under<br />

Left rear<br />

Left<br />

[Procedure for exchanging the drain hose.]<br />

1. Remove the drain hose. 2. Remove the drain cap. 3. Insert the drain cap. <strong>4.</strong> Connect the drain hose.<br />

¡ Loosen and remove the springtype<br />

clamp.<br />

¡ Remove with your hand or a pair<br />

of pliers.<br />

¡ When conducting the central rear piping, use a nipper to cut out knockout<br />

holes in the installation board.<br />

¡ Use a hexagonal wrench to correctly<br />

insert the drain cap which was removed<br />

in 2.<br />

Caution: Be careful because if the cap<br />

is not inserted property, water leak may<br />

occur.<br />

¡ Loosen the spring-type clamp and<br />

securely insert the drain hose.<br />

Caution: Be careful because if the<br />

cap is not inserted properly, water<br />

leak may occur.<br />

Gutter<br />

¡ Do not place the power supply cords<br />

above the gutter, because the air<br />

conditioner is structured in a way where<br />

condensation on the back side is<br />

collected in to the drain pan before<br />

drainage.<br />

Pipes storage area<br />

Wall<br />

Drainage<br />

¡ The drain hose must be fit with a downward slope.<br />

¡ Do not set the drain hose like the following illustrations.<br />

under 5 cm<br />

Too high<br />

The end of the<br />

drain hose is<br />

touching the<br />

water.<br />

It curves like a wave.<br />

Smell from<br />

sewerage drains.<br />

The gap to the The end of the<br />

ground is less drain hose is<br />

than 5 cm.<br />

touching the<br />

sewage drains.<br />

¡ Pour water in the drain pan below the heat exchanger and confirm that the water is drained outside.<br />

¡ If the extension drain hose is indoors, make sure it is insulated using a shielding pipe (not supplied).<br />

Shielding pipe<br />

Drain hose<br />

Extension drain hose<br />

when a part of the extension drain hose is indoors<br />