TVCB Installation<br />
Tightening Sequence<br />
1<br />
3<br />
4<br />
2<br />
Tightening:<br />
Use a criss-cross pattern to tighten the housing bolts.<br />
Tighten closure bolts between 5-7 ft. lbs.<br />
TVCB Troubleshooting<br />
Fault Action - Pulse Disconnect<br />
Pulse Disconnect has the following codes to identify which fault<br />
has occurred:<br />
• Tamper 1 Flash of Disconnect<br />
• Unit Time Out 2 Flashes of Disconnect<br />
• Unit Address 3 Flashes of Disconnect<br />
• Calibration 4 Flashes of Disconnect<br />
• EEPROM 5 Flashes of Disconnect<br />
76