10.07.2015 Views

Practical Industrial Data Networks:Design, Installation and ...

Practical Industrial Data Networks:Design, Installation and ...

Practical Industrial Data Networks:Design, Installation and ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

208 <strong>Practical</strong> <strong>Industrial</strong> <strong>Data</strong> <strong>Networks</strong>: <strong>Design</strong>, <strong>Installation</strong> <strong>and</strong> TroubleshootingFoundation Fieldbus A(H )1To otherHSE linksHSESwitchHigh SpeedEthernet(HSE) LinkHSELinkDeviceFoundation Fieldbus B(H )1Foundation Fieldbus C(H )1Figure 14.6High-speed Ethernet <strong>and</strong> Foundation Fieldbus14.8 Good wiring <strong>and</strong> installation practice with Fieldbus14.8.1 Termination preparationIf care is taken in the preparation of the wiring, there will be fewer problems later <strong>and</strong>minimal maintenance required.A few points to be noted here are:• Strip 50 mm of the cable sheathing from the cable <strong>and</strong> remove the cablefoil.• Strip 6 mm of the insulation from the ends. Watch out to avoid wire nickingor cutting off str<strong>and</strong>s of wire. Use a decent cable-stripping tool.• Crimp a ferrule on the wire ends <strong>and</strong> on the end of the shield wire. Crimpferrules are preferable as they provide a gas tight connection between thewire <strong>and</strong> the ferrule that is corrosion resistant. It is the same metal as theterminal in the wiring block.• An alternative strategy is to twist the wires together <strong>and</strong> to tin them withsolder. Wires can be put directly into the wire terminal but make sure allstr<strong>and</strong>s are in <strong>and</strong> they are not touching each other. Make sure that thestr<strong>and</strong>s are not stretched to breaking point.• Do not attach shield wires together in a field junction box. This can be thecause of ground loops.• Do not ground the shield in more than one place (inadvertently).• Use good wire strippers to avoid damaging the wire.14.8.2 <strong>Installation</strong> of the complete systemOther system components can be installed soon after the cable is installed. This includesthe terminators, power supply, power conditioners, spurs <strong>and</strong> in some cases, the intrinsicsafety barriers. Some devices already have terminator built-in. In that case, be careful thatyou are not doubling up with terminators.Check whether the grounding is correct. There should only be one point for the shieldground point.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!