10.07.2015 Views

Practical Industrial Data Networks:Design, Installation and ...

Practical Industrial Data Networks:Design, Installation and ...

Practical Industrial Data Networks:Design, Installation and ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

250 <strong>Practical</strong> <strong>Industrial</strong> <strong>Data</strong> <strong>Networks</strong>: <strong>Design</strong>, <strong>Installation</strong> <strong>and</strong> Troubleshootingconfirm the actual amount of loss across the link but an easy way to troubleshoot the linkis to replace the transceivers at both ends of the link with new ones.15.6.4.6 AUI problemsExcessive cable lengthThe maximum length of the AUI cable is 50 m assuming that it is a proper IEEE 802.3cable. Some installations use lightweight office grade cables that are limited to 12 m inlength. If these cables are too long, the excessive attenuation can lead to intermittentproblems.DIX latchesThe DIX version of the 15-pin D-connector uses a sliding latch. Unfortunately, not allvendors adhere to the IEEE 802 specifications <strong>and</strong> some use lightweight latch hardware,which results in a connector that can very easily become unstuck. There are basically twosolutions to the problem. The first solution is to use a lightweight (office grade) AUIcable, provided the distance would not be a problem. This places less stress on theconnector. The second solution is to use a special plastic retainer such as the ‘ET Lock’made specifically for this purpose.SQE testThe signal quality error (SQE) test signal is used on all AUI-based equipment to test thecollision circuitry. This method is only used on the old 15-pin AUI-based externaltransceivers (MAUs) <strong>and</strong> sends a short signal burst (about 10 bit times in length) to theNIC just after each frame transmission. This tests both the collision detection circuitry<strong>and</strong> the signal paths. The SQE operation can be observed by means of an LED on theMAU.The SQE signal is only sent from the transceiver to the NIC <strong>and</strong> not on to the networkitself. It does not delay frame transmissions but occurs during the inter-frame gap <strong>and</strong> isnot interpreted as a collision.The SQE test signal must, however, be disabled if an external transceiver (MAU) isattached to a repeater hub. If this is not done, the hub will detect the SQE signal as acollision <strong>and</strong> will issue a jam signal. As this happens after each packet, it can seriouslydelay transmissions over the network. The problem is that it is not possible to detect thiswith a protocol analyzer.15.6.4.7 NIC problemsBasic card diagnosticsThe easiest way to check if a particular NIC is faulty is to replace it with another(working) NIC. Modern NICs for desktop PCs usually have auto-diagnostics included<strong>and</strong> these can be accessed, for example, from the device manager in Windows 95/98.Some cards can even participate in a card-to-card diagnostic. Provided there are twoidentical cards, one can be setup as an initiator <strong>and</strong> one as a responder. Since the twocards will communicate at the data link level, the packets exchanged will, to some extent,contribute to the network traffic but will not affect any other devices or protocols presenton the network.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!